175.3.7
DISPLAY-SIGNL
The following can be displayed:
1.
the numeric values of message classes (TYPE = ALL);
2.
the status of a message class (TYPE = EVT, FORMAT = STA);
3.
the error elements of a message class (TYPE = EVT, FORMAT = SEV);
4.
the data of an error element for a signalling message (TYPE = MID);
5.
the SIT-internal error statistics table (TYPE = SIF);
6.
elements of the error element special table (TYPE = FST).
7.
the current STATUS of SWITCH_TAB, FMTEXT table, action per message ID, locked message IDs
8.
the current system state of the system as CCA, CCB, ADP state, ref clock state, alarms and state of failure switchover
Procedure Overview
Command Code
Parameter
DISPLAY-SIGNL
TYPE=ALL;
TYPE=EVT,EVT=<param>,FORMAT=<param>;
TYPE=MID,CD=<param>,NO=<number>;
TYPE=SIF;
TYPE=FST,[NO=<number>];
TYPE=STATUS;
TYPE=SYSTEM;
Examples
1.
Displaying the numeric values of message classes.
Input:
DISPLAY-SIGNL:ALL;
Output:
DISPLAY-SIGNL:ALL;
H500: AMO SIGNL STARTED
NAMES AND VALUES OF MESSAGE CLASSES:
+------------------------------------------------------------------+
| NAME |VAL.|| NAME |VAL.|| NAME |VAL.|| NAME |VAL.|
+----------|----||----------|----||----------|----||----------|----+
| ALARM | 7C || LNOVER | 02 || AM | 41 || BOARD | 33 |
| CCH | 26 || CG | 6C || : | : || : | : |
| : | : || : | : || SWUINT | 14 || SWUIP | 13 |
| SWUMEM | 12 || SYS | 7F || SYSLEXC | 43 || SYSLOS | 2A |
| SYSQUOFL | 03 || TERM | 04 || : | : || : | : |
| : | : || : | : || VECO | 6F || XENIX | 70 |
+------------------------------------------------------------------+
AMO-SIGNL -... ERROR SIGNALLING CONTROL
DISPLAY COMPLETED;
2.
Interrogation of the status of message class MTS.
Input:
DISPLAY-SIGNL:EVT,MTS,STA;
Output:
DISPLAY-SIGNL:EVT,MTS,STA;
H500: AMO SIGNL STARTED
STATUS OF MTS: LOCK
AMO-SIGNL -... ERROR SIGNALLING CONTROL
DISPLAY COMPLETED;
3.
Display the data for error elements for a message class.
Input:
DISPLAY-SIGNL:EVT,LNOVER,SEV;
Output:
DISPLAY-SIGNL:EVT,LNOVER,SEV;
H500: AMO SIGNL STARTED
+-------------------------------------------------------------------------+
| SIGNALING MESSAGES OF MESSAGE CLASS: LNOVER |
+------+-------+--------+-----+---------------------+---------------------+
| F-NO | MID | OUTPUT | PRI | ASD | CSD |
+------+-------+--------+-----+---------------------+---------------------+
| 0 | F8000 | FREE | E4 | DPT1 DPT2 DPT3 DPT4 | DPT1 DPT2 DPT3 DPT4 |
| | | | | AC MAP | AC MAP |
| 1 | F8001 | FREE | E4 | DPT1 DPT4 MAP | DPT1 DPT2 DPT3 DPT4 |
| | | | | | AC MAP |
+------+-------+--------+-----+---------------------+---------------------+
AMO-SIGNL -... ERROR SIGNALLING CONTROL
DISPLAY COMPLETED;
4.
Display the data for error element 5230 for a signalling message.
Input:
DISPLAY-SIGNL:MID,F,5230;
Output:
DISPLAY-SIGNL:MID,F,5230;
H500: AMO SIGNL STARTED
MESSAGE OUTPUT VALUES : F5230
OUTPUT PERMISSION : FREE PRIORITY : E4
CURRENT OUTPUT DEVICES : DPT1 MAP
CONF. OUTPUT DEVICES : DPT1 MAP
AMO-SIGNL -... ERROR SIGNALLING CONTROL
DISPLAY COMPLETED;
5.
Display the SIT-internal error statistics table.
Input:
DISPLAY-SIGNL:SIT;
Output:
DISPLAY-SIGNL:SIT;
H500: AMO SIGNL STARTED
SIT ERROR STATISTICS COUNTER :
+-------------------------------------+
| DESIGNATION | VALUE |
|-----------------------------|-------|
| SIM BOARD TYPE UNDEF | 00234 |
| SIM CASE EVT FREE | 00013 |
| : | : |
| : | : |
| : | : |
+-------------------------------------+
AMO-SIGNL -... ERROR SIGNALLING CONTROL
DISPLAY COMPLETED;
6.
Display the error element special table
Input:
DISPLAY-SIGNL:FST;
Output:
DISPLAY-SIGNL:FST;
H500: AMO SIGNL STARTED
ERROR ELEMENT SPECIAL TABLE :
+--------+------------+--------+
| NO | ACTION | PRI |
+--------+------------+--------+
| 1090 | INSERV | E4 |
| 1100 | HRCCZZA | M2 |
| 1110 | HRCCZZS | M2 |
| : | : | : |
| : | : | : |
| : | : | : |
+--------+------------+--------+
AMO-SIGNL -... ERROR SIGNALLING CONTROL
DISPLAY COMPLETED;
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.