175.4
Parameter Description
ACTION
Action of dependability system
Type of Input
:
chained single values;
mandatory (ADD, CHANGE)
optional (DELETE)
Possible Values
:
The possible single values are derived from the DB_M_RS_ACTION_SET values.
ASSBLAM
= DB_RS_ASSOC_BLOCK_AM
ASSOCBLK
= DB_RS_ASSOC_BLOCK
CHANOOS
= DB_RS_SM_CHAN_OOS
BDOOS
= DB_RS_BOARD_OOS
HARDREST
= DB_RS_HARD_RESTART
HRCCZZA
= DB_RS_HR_CC_ZZ_ACTIVE
HRCCZZS
= DB_RS_HR_CC_ZZ_STANDBY
HREXSRRE
= DB_RS_HR_EXEC_SR_REFUSED
HRLTGZZA
= DB_RS_HR_LTG_ZZ_ACTIVE
HRLTGZZS
= DB_RS_HR_LTG_ZZ_STANDBY
INSERV
= DB_RS_IN_SERVICE
LBCOOS
= DB_RS_SM_LBC_OOS
LCXREST
= DB_RS_SM_LCX_RESTART
LOCKAM
= DB_RS_SPERREN_AM
NOACT
= DB_RS_NO_ACTION
NOACTAM
= DB_RS_NO_ACTION_AM
OOSAM
= DB_RS_OUT_OF_SERVICE_AM
OUTSERV
= DB_RS_OUT_OF_SERVICE
PARTBLK
= DB_RS_PART_BLOCK
PARBLAM
= DB_RS_PART_BLOCK_AM
RELOAD
= DB_RS_RELOAD
RELOCC
= DB_RS_RELOAD_CC
RELOLTG
= DB_RS_RELOAD_LTG
RELOLTG
= DB_RS_RELOAD_LTG
RESCSN
= DB_RS_RESET_CSN
RESET
= DB_RS_RESET
SOFTREST
= DB_RS_SOFT_RESTART
SPERRE
= DB_RS_SPERREN
SRCC
= DB_RS_SOFT_RESTART_CC
SRLTG
= DB_RS_SOFT_RESTART_LTG
STATIST
= DB_RS_FAULT_STATISTIC
SWITCCG
= DB_RS_SWITCH_CCG
SWITLTG
= DB_RS_SWITCH_LTG
SWITSWU
= DB_RS_SWITCH_SWU
ASD
Actual symbolic devices (to which the message is sent)
Type of Input
:
1 to 8 chained single values, optional
1 to 9 chained single values, optional
Possible Values
:
DPT1, DPT2, DPT3, DPT4,
ATND, AFR, MAP, SICO, rsp.
DPT1, DPT2, DPT3, DPT4,
ATND, MAP, AFR1, AFR2, AFR3 and
ALL (action DELETE only)
NDP4 (action CHANGE/DELETE, TYPE=MID only)
CD
Message key code
Type of Input
:
Single value, mandatory
Possible Values
:
A
(alarm message)
B
(begin message)
E
(end message)
F
(error message)
I
(integrity message; positive)
M
(miscellaneous inf. message; advisory)
U
(undefined error element)
CSD
Configurated symbolic devices (to which the message is sent)
Type of Input
:
1 to 8 chained single values, optional
1 to 9 chained single values, optional
Possible Values
:
DPT1, DPT2, DPT3, DPT4,
ATND, AFR, MAP, SICO, rsp.
DPT1, DPT2, DPT3, DPT4,
ATND, MAP, AFR1, AFR2, AFR3 and
ALL (action DELETE only)
NDP4 (action CHANGE/DELETE, TYPE=MID only)
DEV
symbolic devices to be activated/deactivated for IMPTMSG,FILTER, ...
Type of Input
:
1 to 7 chained single values, optional
Possible Values
:
DPT1, DPT2, DPT3,
ATND, AFR1, AFR2, AFR3
EVT
Event class
Type of Input
:
chained single values or ALL
(when ADD is being carried, a single value only), mandatory
Possible Values
:
The possible values are derived from the DB_M_RS_EVT_SET values.
ACM
= DB_RS_E_ACM
ALARM
= DB_RS_E_ALARMWORT
LNOVER
= DB_RS_E_ALUM
AM
= DB_RS_E_AM
AMO
= DB_RS_E_AMO
BOARD
= DB_RS_E_BOARD
CCH
= DB_RS_E_CCH
CG
= DB_RS_E_CG
CHACOM
= DB_RS_E_CHARGE_COM
CIR
= DB_RS_E_CIR
CMS
= DB_RS_E_CMS
CONF
= DB_RS_E_CONF
CP
= DB_RS_E_CP
CPMSG
= DB_RS_E_CP_MSG
DB
= DB_RS_E_DB
DBSYNC
= DB_RS_E_DBSYNC
DCL
= DB_RS_E_DCL
DEP
= DB_RS_E_DEP
DH
= DB_RS_E_DH
DMS
= DB_RS_E_DMS
DRIVE
= DB_RS_E_DRIVE
GOINS
= DB_RS_E_GO_IN_SERVICE
HRCCA
= DB_RS_E_HR_CC_Z_A
HRCCSB
= DB_RS_E_HR_CC_Z_SB
HWY
= DB_RS_E_HWY
IOCC
= DB_RS_E_IOCC
IOCG
= DB_RS_E_IOCG
IOPSDC
= DB_RS_E_IOPD_DC
LBCLB
= DB_RS_E_LBC_LB
LCX
= DB_RS_E_LCX
LCXCHAN
= DB_RS_E_LCX_CHAN
LNSMOFF
= DB_RS_E_LTG_SM_OFF
LNSMON
= DB_RS_E_LTG_SM_ON
LTUC
= DB_RS_E_LTUC
MAP
= DB_RS_E_SIG_MELD
MBU
= DB_RS_E_MBU
MODSTATE
= DB_RS_E_MOD_ZUST
MTS
= DB_RS_E_MTS
NC
= DB_RS_E_NC
NCCALARM
= DB_RS_E_NCC_DEP_ALARM
NCCSBR
= DB_RS_E_NCC_START_SBR
NCCSTART
= DB_RS_E_NCC_START
NCCTIMER
= DB_RS_E_NCC_DEP_TIMER
NCCUPDAT
= DB_RS_E_NCC_UPDATE
OS
= DB_RS_E_OS
PCG
= DB_RS_E_PCG
PM
= DB_RS_E_PM
PP
= DB_RS_E_PP
PPH
= DB_RS_E_PPH
PROCINT
= DB_RS_E_PROC_INTERR
PS
= DB_RS_E_PS
PWFAIL
= DB_RS_E_NETZ_AUSF
REC
= DB_RS_E_REC
RESTSM
= DB_RS_E_RESTART_SM
SIT
= DB_RS_E_FEH_INBETRN_BE_AN
SITEND
= DB_RS_E_FEH_INBETRN_BE_EN
SIU
= DB_RS_E_SIU
SM
= DB_RS_E_SM
SMAM
= DB_RS_E_SM_AM
SMAS
= DB_RS_E_SM_AS
SMCR
= DB_RS_E_SM_CR
SMDB
= DB_RS_E_SM_DB
SMDEP
= DB_RS_E_SM_DEP
SMDP
= DB_RS_E_SM_DP
SMINS
= DB_RS_E_SM_INS
SMIP
= DB_RS_E_SM_IP
SMMB
= DB_RS_E_SM_MB
SMMEM
= DB_RS_E_SM_MEM
SMNACK
= DB_RS_E_SM_NEGATIVE_ACK
SRCC
= DB_RS_E_SR_CC
STBY
= DB_RS_E_STBY
SWUDP
= DB_RS_E_SWU_DP
SWUINT
= DB_RS_E_SWU_INT
SWUIP
= DB_RS_E_SWU_IP
SWUMEM
= DB_RS_E_SWU_MEM
SYS
= DB_RS_E_SYS
SYSLEXC
= DB_RS_E_SYSL_EXCEPT
SYSLOS
= DB_RS_E_SYSL_OS_ERROR
SYSQUOFL
= DB_RS_E_SYSDEP_QUEUE_OFLOW
TERM
= DB_RS_E_TERM
TIMEDATE
= DB_RS_E_TIME_DATE
VECO
= DB_RS_E_VECO
XENIX
= DB_RS_E_XENIX
ALL (actions DELETE, SET and DISPLAY only)
FORMAT
Output format for event class
Type of Input
:
Single value, mandatory
Possible Values
:
STA (output, status)
SEV (output, data of FET entries)
IDX
Index of events in the FET (fault element table)
Type of Input
:
Single value, mandatory
Possible Values
:
0000 - 9999
NEWCD
New message key code
Type of Input
:
Single value, mandatory
Possible Values
:
A
(alarm message)
B
(begin message)
E
(end message)
F
(error message)
I
(integrity message; positive)
M
(miscellaneous inf. message; advisory)
U
(undefined error element)
NEWNO
New fault number
Type of Input
:
Single value, mandatory
Possible Values
:
See volume on Dependability
A30950-S37-X110-*-20, Section 6
NO
Message number
Type of Input
:
Chained single values, ranges,
mandatory
optional (DISPLAY of type FST)
Possible Values
:
See volume on Dependability
A30950-S37-X110-*-20, Section 6
OLDCD
Old message key code
Type of Input
:
Single value, mandatory
Possible Values
:
A
(alarm message)
B
(begin message)
E
(end message)
F
(error message)
I
(integrity message; positive)
M
(miscellaneous inf. message; advisory)
U
(undefined error element)
OLDNO
Old message number
Type of Input
:
Single value, mandatory
Possible Values
:
See SHB Volume ’Dependability’
A30950-S37-X110-*-20, Section 6
OUT
Output authorization for signalling events
Type of Input
:
Single value, optional
Possible Values
:
FREE, LOCK
PRI
Message priority
Type of Input
:
Single value, optional
mandatory (ADD, CHANGE of type FST)
Possible Values
:
E1 to E9
M1 to M9
SEL
Selection
Type of Input
:
Single value, mandatory
Possible Values
:
Y, N
STATE
Status of event class
Type of Input
:
Single value, optional
Possible Values
:
UNDEF, LOCK, FREE, OOS
SWITCH
Desired switch options
Type of Input
:
Single value, mandatory
Possible Values
:
IMPTMSG
= forced output of important messages
FILTER
= filter active
ALLMSG
= forced output of all messages
SHORTFM
= short display
TEXT
user defined text string
Type of Input
:
Single value, mandatoryl
Possible Values
:
any textstring of up to 74 characters enclosed in ""
TYPE
Desired error signalling control options
Type of Input
:
Single value, mandatory
Possible Values
:
AL
= Alarm memory
ALL
= Names and values of all message classes
EVT
= EVENT
FST
= Error element special table
MID
= Message Identification
NID
= New Message Identification
SIF
= SIT-internal fault statistics table
STATUS
Status information
SYSTEM
SYSTEM information
Parameter Groups
Parameter groups have been defined in the following actions:
•
CHANGE (TYPE=EVT): parameters STATE, ASD and CSD;
•
CHANGE (TYPE=MID): parameters OUT, PRI, ASD and CSD;
•
DELETE (TYPE=EVT, MID): parameters ASD and CSD;
•
ACTIVATE : parameter DEV
•
DEACTIVATE: parameter DEV
At least one parameter must be specified in each case.
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.