178.2.3
SWITCHOVER-SONUS
Change the function mode of the switchover task.
Three different modes can be chosen from:
•
HD : read the switchover dates from the table in a hard disk file;
•
AUTO : the task computes the switchover dates
–
according to the directives of the European Community (EU) regarding DLS / standard time switchover in european program systems
(DEVELOPMENT LINE = EUROPE DEVELOPMENT at DISPLAY-
DBC
;)
–
according to US-standard on american program systems
(DEVELOPMENT LINE = US DEVELOPMENT at DISPLAY-
DBC
;)
•
OFF : the task is deactivated
The AMO reads the table and the switchover mark will be changed according to the input.
If there is no SONUS-file on the hard disk, one will be created, similar to the ADD branch. The table of switchover dates will be initialised with dummy information. Thereafter the switchover mark will be adjusted according to the input command.
Procedure Overview
Command Code
Parameter
SWITCHOVER-SONUS
FUNCT=<param>;
Example
Switch over the resident task to automatic
Input:
SWITCHOVER-SONUS:AUTO;
Output:
H04: US-STANDARD APPLIES FOR THE AUTOMATIC TIME-SWITCHOVER.
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.