186.2.1
ADD-TABT
Enter rate periods and the associated rate types into the rate period table.
A maximum of 24 entries can be made, the limit value for the last entry must be 2400 hrs. During entry, the AMO requests the following parameter sequence: limit value, monday rate type, tuesday rate type, wednesday rate type, thursday rate type, friday rate type, saturday rate type, and sunday rate type.
The AMO requests this parameter sequence until 2400 hrs. is entered as the limit value (maximum of 24 times).
The limit values are entered into the data base in ascending order.
Procedure Overview
Command Code
Parameter
ADD-TABT
LT=<number>,TARTYPMO=<string>,TARTYPTU=<string> ,TARTYPWE=<string>,TARTYPTH=<string>,TARTYPFR=<string>
,TARTYPSA=<string>,TARTYPSU=<string>
,SEGTBLNO=<number>;
Example
1.
Creation of a rate period table number 1.
Input:
ADD-TABT:06-00,NTAR1,NTAR1,NTAR1,NTAR1,NTAR1,NTAR1,NTAR1,1;
ADD-TABT:08-00,NTAR2,NTAR2,NTAR2,NTAR2,NTAR2,NTAR2,NTAR2,1;
ADD-TABT:18-00,DTAR,DTAR,DTAR,DTAR,DTAR,DTAR,DTAR,1;
ADD-TABT:22-00,NTAR3,NTAR3,NTAR3,NTAR3,NTAR3,NTAR3,NTAR3,1;
ADD-TABT:23-00,NTAR4,NTAR4,NTAR4,NTAR4,NTAR4,NTAR4,NTAR4,1;