199.5.2
Advisories
H01:
PLEASE SPECIFY LTG NUMBER
H02:
SYSTEM UNIT NOT DUPLICATED
H03:
PARAMETER LOOPBACK HAS BEEN IGNORED
H04:
TEST IN PROGRESS
H05:
PARAMETER TSI HAS BEEN IGNORED
H06:
PARAMETER SELFTEST IS SET YES AUTOMATICALLY
H07:
TEST: EXTERNAL REMOTE LOOPBACK TMD/T1DN/SLMN-T1
-----------------------------------------------
BOARD <pen> ** BOARD IS REMOTE BOARD **
** INTERNAL REMOTE LOOPBACK (IDC) ACTIVATED **
PLEASE CONTINUE TEST ON LOCAL BOARD (TEST-TSU:LOOPBACK = EDC)
H08:
TEST: EXTERNAL REMOTE LOOPBACK TMD/T1DN/SLMN-T1
-----------------------------------------------
BOARD <pen> ** BOARD IS LOCAL BOARD **
** TEST EDC COMPLETED **
PLEASE DEACTIVATE THE INTERNAL REMOTE LOOPBACK ON THE REMOTE BOARD
(TEST-TSU:....LOOPBACK = IDL)
H09:
TEST: EXTERNAL REMOTE LOOPBACK TMD/T1DN/SLMN-T1
-----------------------------------------------
BOARD <pen> ** BOARD IS REMOTE BOARD **
INTERNAL REMOTE LOOPBACK (IDC) DEACTIVATED
H10:
AFTER CALL OF ’DIAGNOSE-TSU’ TEST ERRORS ARE TREATED AUTOMATICALLY
BY FAULT ANALYSIS ! IN THIS CASE FA CAN CAUSE LOCKS,SWITCHING OR RESTARTS!
(IN CASE OF ERRORS SIGNALLING MESSAGES ARE DISPLAYED
ON SCREEN IF OUTPUT IS ASSIGNED RIGHT)
H11:
TEST: EXTERNAL REMOTE PAYLOAD LOOPBACK TMD/SLMN-T1
--------------------------------------------------
BOARD <pen> ** BOARD IS REMOTE BOARD **
** INTERNAL REMOTE PAYLOAD LOOPBACK (IPON) ACTIVATED
PLEASE CONTINUE TEST ON LOCAL BOARD (TEST-TSU: ..LOOPBACK = EDC)
H12:
TEST: EXTERNAL REMOTE PAYLOAD LOOPBACK TMD/SLMN-T1
--------------------------------------------------
BOARD <pen> ** BOARD IS REMOTE BOARD **
INTERNAL REMOTE PAYLOAD LOOPBACK (IPON) DEACTIVATED
H13:
FRAME TABLE CAN NOT BE LOADED FROM HARD DISK
H14:
TSI IS SET TO 1 FOR LINEPOWER TEST
H15:
ACTIONS OF FA CAN LAST ABOUT 5 MINUTES WHEN MAJOR DEFECTS
OCCUR ON CSN HIGHWAY !
H16:
ALL TERMINALS AT THIS CIRCUIT ARE TESTED
H17:
THE TESTS CAN BE STOPPED USING CTRL/X
WHILE DISPLAYING TEST RESULTS (PLEASE DO NOT USE ’CANCEL:..’ TO STOP AMO TSU !)
H18:
LOCKS ARE THE RESULTS OF THIS TEST ! IT MAY NOT BE STARTED IN NORMAL OPERATION !! LAST CHANCE TO STOP (CTRL/X) !
H19:
SUBSCRIBER STATE HAS CHANGED DURING MEASUREMENT ! THE MEASUREMENT RESULTS ARE PROBABLY NOT USEFUL ! PLEASE REPEAT THE TEST !
H20:
SUBSCRIBER STATE (ONHHOOK OR OFFHOOK) CAN NOT BE DETERMINED AT THE MOMENT (THERE IS NO DIFFERENCE IN MEASUREMENT BETWEEN ONHOOK AND OFFHOOK LOOP).
H21:
SIMPLE LINECHECK : SEE IMPORTANT INFORMATION IN SERVICE MANUAL ! THIS TEST SHOULD BE CARRIED OUT A FEW TIMES ! (TEST USEFUL UP TO 8 KM ONLY)
H22:
TIMESLOT IS SET TO ’1’
H23:
TIMESLOT IS CHOSEN BY RTO.
H24:
HIGHWAY IS CHOSEN BY RTO.
H25:
THE BOARD HIGHWAY TEST CAN ONLY BE STARTED WITHOUT DIFFICULTIES, IF IT IS NOT ACTIVATED AS A ROUTINE TEST BY AMO
FUNSU
. PLEASE CHECK BY USING AMO
FUNSU
, WETHER THE TEST IS ACTIVE.
IF IT IS SO, THE ROUTINE TEST HAS TO BE DEACTIVATED BEFORE RUNNING THE MANUAL TEST AND IT HAS TO BE ACTIVATED AFTERWARDS.
H26:
WRONG USAGE OF THIS FUNCTION CAN CAUSE HEAVY PROBLEMS IN THE SWITCH ! PLEASE CHECK THE INPUT PARAMETERS AND SKIP FUNCTION IF YOU ARE NOT SURE ! DO YOU WANT TO CONTINUE THIS FUNCTION ?
H27:
COMMAND EXECUTION SUCCESSFULLY DONE
H28:
COMMAND HAS NOT BEEN EXECUTED