200.3
Parameter description
BCHLFACT
The charge calculation factor for a B-Channel, in percent
Type of input
:
Single value,
15th parameter of a min-1-Group (TBL=WOCU) (CHANGE)
Possible values
:
0 to 999
Default value
:
100
CARRIER
Number of the carrier of a connection
Type of input
:
Single value,
required (ADD, CHANGE)
optional (DELETE)
Possible values
:
0 to 9
CATPTY
Category of calling party
Type of input
:
Single value,
required (ADD, CHANGE)
Possible values
:
NORM
= Normal Subscriber
SCRSPC
= Subscriber with Special Charging
PUPHON
= Public Phone
MTEQ
= Maintenance Equipment
CHPER
Mark for changing the period
Type of input
:
Single value, required (ADD)
17th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
Y
= Costs are calculated based on the actual time of day
N
= Costs are calculated based on connection start time of day (no section change)
Default value
:
Y
COMPOS
Position of comma in cdr output at display console
Works only on tariff tables without charge information
Type of Input
Single Value, required (CHANGE)
Possible values
:
-3, -2, -1, 0, +1, +2, +3, 2T, 3T, 2HT and 3HT
Default value
:
+2
ELEMENT
Element
Type of Input
:
Single Value, required (DELETE, CHANGE)
Possible values
:
COMPOS
= view ’COMPOS’
VAT
= view ’FAT’
FACTOR
Multiplication factor in tenth percent, for the costs of connection with charge information
Type of input
:
Single value,
required (ADD)
6th parameter of a min-1-group (TBL=WCU) (CHANGE)
Possible values
:
0000 to 9999
0000 = Costs NULL (Multiplication by 0)
1000 = Received costs are unchanged
(Multiplication by 1)
9999 = Received costs are multiplied by 9,999
Default Value
:
1000
FIXDAY
Number of pulses to be sent immediately (basic charge) for DAY
Type of input
:
Single value,
required (ADD)
1st parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 15
FIXN1
Number of pulses to be sent immediately (basic charge) for N1
Type of input
:
Single value,
required (ADD)
4th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 15
FIXN2
Number of pulses to be sent immediately (basic charge) for N2
Type of input
:
Single value,
required (ADD)
7th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 15
FIXN3
Number of pulses to be sent immediately (basic charge) for N3
Type of input
:
Single value,
required (ADD)
10th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 15
FIXN4
Number of pulses to be sent immediately (basic charge) for N4
Type of input
:
Single value,
required (ADD)
13th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 15
FPLSDAY
Delay time for the first pulse (in 10 ms) for DAY
Type of input
:
Single value,
required (ADD)
2nd parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 999999
= Static delay in 10 ms
KA
= Karlson added random value
KM
= Karlson modified random value
K
= Karlson random values
FPLSN1
Delay time for the first pulse (in 10 ms) for N1
Type of input
:
Single value,
required (ADD)
5th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 999999
= Static delay in 10 ms
KA
= Karlson added random value
KM
= Karlson modified random value
K
= Karlson random values
FPLSN2
Delay time for the first pulse (in 10 ms) for N2
Type of input
:
Single value,
required (ADD)
8th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 999999
= Static delay in 10 ms
KA
= Karlson added random value
KM
= Karlson modified random value
K
= Karlson random values
FPLSN3
Delay time for the first pulse (in 10 ms) for N3
Type of input
:
Single value,
required (ADD)
11th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 999999
= Static delay in 10 ms
KA
= Karlson added random value
KM
= Karlson modified random value
K
= Karlson random values
FPLSN4
Delay time for the first pulse (in 10 ms) for N4
Type of input
:
Single value,
required (ADD)
14th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 999999
= Static delay in 10 ms
KA
= Karlson added random value
KM
= Karlson modified random value
K
= Karlson random values
GROUPNO
Number of a tariff group table
Type of input
:
Single value, required (ADD)
optional (DISPLAY, REGENERATE)
Possible values
:
0 to 5
GRTARRGN
Graduated tariff region
Type of input
:
Single value
2nd parameter of a min-1-group (TBL=WCU) (CHANGE)
Possible values
:
1 to 4
INTDAY
Time units in 1/100 seconds for day tariff
Type of input
:
Single value,
required (ADD)
1st parameter of a min-1-group (TBL=WOCU) (CHANGE)
Possible values
:
maximum 5 digits
00001 to 99999 (see Appendix)
INTNT1
Time units in 1/100 seconds for night tariff 1
Type of input
:
Single value,
required (ADD)
3rd parameter of a min-1-group (TBL=WOCU) (CHANGE)
Possible values
:
maximum 5 digits
00001 to 99999 (see Appendix)
INTNT2
Time units in 1/100 seconds for night tariff 2
Type of input
:
Single value,
required (ADD)
5th parameter of a min-1-group (TBL=WOCU) (CHANGE)
Possible values
:
maximum 5 digits
00001 to 99999 (see Appendix)
INTNT3
Time units in 1/100 seconds for night tariff 3
Type of input
:
Single value,
required (ADD)
7th parameter of a min-1-group (TBL=WOCU) (CHANGE)
Possible values
:
maximum 5 digits
00001 to 99999 (see Appendix)
INTNT4
Time units in 1/100 seconds for night tariff 4
Type of input
:
Single value,
required (ADD)
9th parameter of a min-1-group (TBL=WOCU) (CHANGE)
Possible values
:
maximum 5 digits
00001 to 99999 (see Appendix)
LT
Limit value of units, valid until the entered value
Type of input
:
Single value, required (ADD)
3rd parameter of a min-1-group (TBL=WCU) (CHANGE)
Possible values
:
0 to 9999
LT1
Limit value of units, valid until the entered value
Type of input
:
Single value, required (ADD)
Possible values
:
0 to 9999
LT2
Limit value of units, valid until the entered value
Type of input
:
Single value, required (ADD)
Possible values
:
0 to 9999
LT3
Limit value of units, valid until the entered value
Type of input
:
Single value, required (ADD)
Possible values
:
0 to 9999
METHOD
Cost calculation method
Type of input
:
Single value,
required (ADD)
5th parameter of a min-1-group (TBL=WCU) (CHANGE)
Possible values
:
FACTOR
=Costs are multiplied by FACTOR
UNITS
=Costs are result of back calculated charge units
NTAR1
Currency value per Time units (NTAR1)
Type of input
:
Single value,
required (ADD)
4th parameter of a min-1-group (TBL=WOCU) (CHANGE)
Possible values
:
maximum 4 digits
0000 to 9999 (see Appendix)
NTAR2
Currency value per Time units (NTAR2)
Type of input
:
Single value,
required (ADD)
6th parameter of a min-1-group (TBL=WOCU) (CHANGE)
Possible values
:
maximum 4 digits
0000 to 9999 (see Appendix)
NTAR3
Currency value per Time units (NTAR3 )
Type of input
:
Single value,
required (ADD)
8th parameter of a min-1-group (TBL=WOCU) (CHANGE)
Possible values
:
maximum 4 digits
0000 to 9999 (see Appendix)
NTAR4
Currency value per Time units (NTAR4)
Type of input
:
Single value,
required (ADD)
10th parameter of a min-1-group (TBL=WOCU) (CHANGE)
Possible values
:
maximum 4 digits
0000 to 9999 (see Appendix)
PPLSDAY
Period for the periodic pulses (in 10 ms) for DAY
Type of input
:
Single value
required (ADD)
3rd parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 999999
PPLSN1
Period for the periodic pulses (in 10 ms) for N1
Type of input
:
Single value
required (ADD)
6th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 999999
PPLSN2
Period for the periodic pulses (in 10 ms) for N2
Type of input
:
Single value
required (ADD)
9th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 999999
PPLSN3
Period for the periodic pulses (in 10 ms) for N3
Type of input
:
Single value
required (ADD)
12th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 999999
PPLSN4
Period for the periodic pulses (in 10 ms) for N4
Type of input
:
Single value
required (ADD)
15th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
0 to 999999
SEGTBLNO
Number of segmentation table for time of day
Type of input
:
Single value,
required (ADD)
13th parameter of a min-1-group (TBL=WOCU) (CHANGE)
16th parameter of a min-1-group (TBL=CLK) (CHANGE)
Possible values
:
1 to 25
SERVICE
Communication service
Type of input
:
Single value, chained single values
required (ADD, CHANGE)
optional (DELETE)
Possible values
:
ALL
= All Services
DTE
= Data terminal equipment
FAX
= Telefax
VOICE
= Voice connection
TAR
Currency value per call charge unit
Type of input
:
Single value,
required (DIALOG01)
4th parameter of a min-1-group (TBL=WCU) (CHANGE)
Possible values
:
maximum 4 digits
0000 to 9999 (see Appendix)
TAR1
Currency value per call charge unit (for 1st limit)
Type of input
:
Single value, required (ADD)
Possible values
:
maximum 4 digits
0000 to 9999 (see Appendix)
TAR2
Currency value per call charge unit (for 2nd limit)
Type of input
:
Single value, required (ADD)
Possible values
:
maximum 4 digits
0000 to 9999 (see Appendix)
TAR3
Currency value per call charge unit (for 3rd limit)
Type of input
:
Single value, required (ADD)
Possible values
:
maximum 4 digits
0000 to 9999 (see Appendix)
TAR4
Currency value per call charge unit (for 4th limit)
Type of input
:
Single value, required (ADD)
Possible values
:
maximum 4 digits
0000 to 9999 (see Appendix)
TARBAS
Currency value for the base charge of a connection without charge information (in 1/100-ths or in 1/1000-ths currency units)
Type of input
:
Single value,
required (ADD)
11th parameter of a min-1-group (TBL=WOCU) (CHANGE)
Possible values
:
maximum 5 characters
-9999 to +9999 (see Appendix)
TARDAY
Currency value per time units (INTDAY)
Type of input
:
Single value,
required (ADD)
2nd parameter of a min-1-group (TBL=WOCU) (CHANGE)
Possible values
:
maximum 4 digits
0000 to 9999 (see Appendix)
TARMIN
Currency value for the minimum charge of a connection
Type of input
:
Single value,
required (ADD)
1st parameter of a min-1-group (TBL=WCU) (CHANGE)
12th parameter of a min-1-group (TBL=WOCU) (CHANGE)
Possible values
:
maximum 4 digits
0000 to 9999 (see Appendix)
TARTBLNO
Number of a tariff table
Type of input
:
Single value, required (ADD)
optional (DISPLAY)
Possible values
:
1 to 9
TBL
Entry of a tariff or tariff group table
Type of input
:
Single value, required
optional (DISPLAY)
Possible values
:
WCU
= Table with charge information
WOCU
= Table without charge information
GRP
= Tariff group table
CLK
= Table with clock information
GEN
= General charge information
VAT
Value added tax in tenth percent
Type of Input
Single value,
required (CHANGE)
Possible Values
:
0 to 9999
Standard Value
:
0
ZONE
Distance zone for connections without call charge information
Type of input
:
Single value, required (ADD, CHANGE)
optional (DELETE, DISPLAY)
Possible values
:
INC01
1st incoming zone
INC0n
nth incoming zone
INC09
9th incoming zone
ABR01
1st abroad zone
ABRnn
nnth abroad zone
ABR99
99th abroad zone
DIST01
1st distance zone
DISTnn
nnth distance zone
DIST50
50th distance zone
FREE
Charge free
CHINFO
Charge information from carrier
INT01
1st internal zone
INT0n
nth internal zone
INT09
9th internal zone
NEAR
Near zone
LOC
Local zone
TIE01
1st zone for tie connections
TIE0n
nth zone for tie connections
TIE09
9th zone for tie connections
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.