203.4
Parameter Description
STATE
State of the automatic update
Type of Input
:
Single value, optional
Possible Values
:
OFF
= deactivated
ON
= activated
SUSY
DB subsystems to be updated
Type of Input
:
Single value, optional
Possible Values
:
ALL
= all
DELTA
= where data has been changed
Default Value
:
DELTA
UNIT
Mnemonic code of server in which the AMO is to be executed
Type of Input
:
Single value, mandatory
Possible Values
:
BP
= active base processor (A or B) of SWU
BPS
= standby base processor (A or B) of SWU
BPA
= base processor A of SWU
BPB
= base processor B of SWU
A1
= administration and data server (ADS)
C1
= call charge server (CM)
V1-V3
= voice mail server (VMS)
T1-T3
= telecommunication server (TCS)
UPDT01
Time when updating is to start
to
Type of Input
:
Single value, optional
UPDT12
Possible Values
:
H-Mi
H
= hour
Mi
= minute
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.