DELLAP
After issuing DEACT-USSU ,an AP (Access Point) shelf deconfiguration requires one more step to release the connection. This is done by sending "stop connection" message to FA.For this purpose the EXEC branch has the DELLAP mode.
Before sending the ’stop message" the DC status and FA control flags of the concerned LTU are checked. ( DC status has to be "MAN_AMO".)
Improper DC status and FA flags (internal) cause the error message F34.
If the connection is shut down properly the advisory message H30 is issued and the FA flag of the concerned LTU is changed to "CONNECTION_DOWN" by AMO-USSU.