205.3
Parameter Description
ANSW
Answer
Type of Input
:
Single value, optional
Possible values
:
NO
YES
Default Value
:
NO
FILES
To specify LW-
Files to be loaded
Type of Input
concat. with & , optional
Possible values
SIUTONES
=SIU initialization data file -TONES
SIURECV
=SIU initialization data file -RECEIVERS
SIUANN
=SIU initialization data file -ANNOUNCEMENTS
SIUMOH
=SIU initialization data file -MUSIC ON HOLD
SIUTDS
=SIU initialization data file -TDS
LW
=LW subsystem of NCUI board
ALLSIU
=All possible SIU initialization data files.
ALL
=All possible loadable files
Default Value
ALL
HALF
For specifying the unit half to be activated.
Type of Input
:
Single value, optional
Possible Values
:
ACT
= active unit half
SBY
= inactive half (standby)
PARTA
= Unit half A
PARTB
= Unit half B
Default Value
:
ACT
LOADTYPE
Type of loading
Type of Input
:
Single value, optional
Possible values
:
CL
Conditional loading
UL
Unconditional loading
Default Value
:
CL
LTG
Number of Line Trunk Group
Type of Input
:
Single value, optional
Possible Values
:
1
LTU
Number of Line Trunk Unit
Type of Input
:
single value,
mandatory for single LTG systems
optional otherwise
and optional for EXEC-USSU:CONFAP, DELLAP and UPDATAP branches
Possible Values
:
1 to 99
1 to 15 for the 600-ECX
1 to 6 for the 600
1 to 8 for the 600-EC
1 to 2 for the 180 CN
1 to 4 for the 3000
MODE
To specify the
mode of the opera.
Type of Input
Single value,mandatory
Possible values
CONFAP
=Initiate start connection message
DELLAP
=Initiate stop connection message
UPDATAP
=initiate update connection message
NCUILOAD
=initiate background loading of LW files
NO
For specifying the HDLC-DCL highway number
Type of Input
:
Single value, mandatory
Possible Values
:
1 to 16
REFOFF
Switch off reference clock generator if desired
Type of Input
:
Single value
optional
Possible Values
:
Y, N, PROMPT
Y
= switch of if applicable
N
= do not switch off
PROMPT
= prompt if required
Default Value
:
PROMPT
TYPE
Type of the RTM board activation
Type of Input
Single value, mandatory
Possible Values
BOARD
= Board
DATA
= Data
UNIT
Name of system unit to be activated
Type of Input
:
Single value, mandatory
Possible Values
:
LTG
= Peripheral
SIU
= SIU
HDLC
= HDLC-highway
RTM
= RTM
DLLOGFL
= Download of RTM log files.
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG. All other trademarks herein are the property of their respective owners.