206 VADSM - Administration of NMC alarms in the SM

A global filter for alarm messages has been added to the system to prevent not-service-relevant messages. AMO-SIGNL defines the minimum priority of the alarms which are forwarded by SIT. The priority of each single alarm can be changed by AMO-VADSM.
e)
+=======+=========+=========+========+========+=====+==+==+=====================+
I ALARM I THRSHD1 ! THRSHD2 ! TIME1 ! TIME2 !TIME !PR!HW| NAME I
I NO I in % ! in % ! in sec ! in sec ! in h! !CO| I
+-------+---------+---------+--------+--------+-----+--+--+---------------------+
I 0 I DEACT ! 1 ! 0 ! 600 ! 0 !E0!SU| SERVICE TELETYP I
I 1 I DEACT ! 1 ! 0 ! 600 ! 0 !E0!SU| SERVICE UTC I
I 2 I DEACT ! 1 ! 0 ! 600 ! 0 !E0!SU| SERVICE TTX I
I 3 I DEACT ! 1 ! 0 ! 600 ! 0 !E0!SU| SERVICE FAX I
I 4 I DEACT ! 1 ! 0 ! 600 ! 0 !E0!SU| SERVICE VOICE I
I 5 I DEACT ! 1 ! 0 ! 600 ! 0 !E0!SU| SERVICE XENIX I
I 6 I DEACT ! 1 ! 0 ! 600 ! 0 !E0!SU| SERVICE BSC I
I 7 I DEACT ! 1 ! 0 ! 600 ! 0 !E0!SU| SERVICE ISO I
I 8 I DEACT ! 1 ! 0 ! 600 ! 0 !E0!SU| SERVICE IBM I
I 9 I - ! - ! - ! - ! 0 !E0!SU| NOT USED I
I 10 I - ! - ! - ! - ! 0 !E0!SU| NOT USED I
I 11 I - ! - ! - ! - ! 0 !E0!SU| NOT USED I
I 12 I - ! - ! - ! - ! 0 !E0!SU| NOT USED I
I 13 I - ! - ! - ! - ! 0 !E0!SU| NOT USED I
I 14 I DEAKT ! 1 ! 0 ! 600 ! 0 !E0!SU| IS FLASH MEMORY I
I 15 I DEAKT ! 1 ! 0 ! 600 ! 0 !E0!SU| SM FLASH MEMORY I
I 16 I DEAKT ! 1 ! 0 ! 600 ! 0 !E0!SU| IS DAT RECORDER I
I 17 I DEAKT ! 1 ! 0 ! 600 ! 0 !E0!SU| SM DAT RECORDER I
I 18 I DEACT ! 1 ! 0 ! 600 ! 0 !E0!SU| IS HARD DISK I
I 19 I DEACT ! 1 ! 0 ! 600 ! 0 !E0!SU| IS CARTRIDGE I
I 20 I DEACT ! 1 ! 0 ! 600 ! 0 !E01SU| IS TAPE I
I 21 I DEACT ! 1 ! 0 ! 600 ! 0 !E0!SU| SM HARD DISK I
I 22 I - ! - ! - ! - ! 0 !E0!SU| NOT USED I
I 23 I - ! - ! - ! - ! 0 !E0!SU| NOT USED I
+=======+========+=========+========+========+=====+==+==+=====================+
I THRESHD1 ... Threshold value for minor alarm (in percent) I
I THRESHD2 ... Threshold value for major alarm (in percent) I
I TIME1 ...... Validation time for minor alarm (in seconds) I
I TIME2 ...... Validation time for major alarm (in seconds) I
I TIME ...... Validation time for single device alarm (in hours) I
I PR ...... Priority of the alarm; HW-CO .....HW Contact (Alarm contact) I
I DEACT ...... Major/minor alarm has been deactivated I
I - .......... Alarm number not used (reserved) I
+==============================================================================+