206.3.1
CHANGE-VADSM
CHANGE-VADSM can be used to change threshold values and validation times. An alarm is deactivated, when its threshold is set to 65535.
In case of a change of the threshold values of the central alarm 13 the error message
F09: CHANGE OF VALIDATION DATA FOR ALARM 13 NOT POSSIBLE
is displayed.
The threshold values of some central SM alarms cannot be changed (see Table 1).
Procedure Overview
Command Code
Parameter
CHANGE-VADSM
[UNIT=<param>],
ALARMGR=CENTRAL,ALARMNO=<range>
,{THRESHD1=<number>,THRESHD2=<number>
,TIME1=<number>,TIME2=<number>,TIME=<number>,
,PRIO=<number>,HWCONT=<param>};
|
ALARMGR=PERIPHER,ALARMNO=<range>
,{THRESHD1=<number>,THRESHD2=<number>
,TIME1=<number>,TIME2=<number>,TIME=<number>,
,PRIO=<number>,HWCONT=<param>};
Example
Change the threshold value for the major alarm of central alarm 21 in the ISp.
Input:
CHANGE-VADSM:UNIT=A1,ALARMGR=CENTRAL,ALARMNR=21,THRESHD1=20;