206.3.4
DISPLAY-VADSM
Procedure Overview
Command Code
Parameter
DISPLAY-VADSM
[UNIT=<param>],
[ALARMGR=CENTRAL],[ALARMNO=<range>];
|
[ALARMGR=PERIPHER],[ALARMNO=<range>];
Examples
1.
Display peripheral SM alarms 0 to 2 in the ISp.
Input:
DISPLAY-VADSM: ,PERIPHERAL,0&&2;
Output:
+================================================================================+
| ALARM GROUP: PERIPHERAL SM ALARMS | +===+=======+=======+=====+====+=====+=====+=====+====+==+==+====================+
|AL.|THRSHD1|THRSHD2|ERR. |ERR.|TOTAL|TIME1|TIME2|TIME|PR|HW| NAME |
|NO.|IN % |IN % |ABSOL|IN %| |[SEC]|[SEC]| [H]| |CO| |
+---+-------+-------+-----+----+-----+-----+-----+----+--+--+--------------------+
| 0 | DEACT | 1 | 0 | 0 | 0 | 0 | 600 | 0 |E0|SU| SERVICE TELETYP |
| 1 | DEACT | 1 | 0 | 0 | 0 | 0 | 600 | 0 |E0|SU| SERVICE TELETYP |
| 2 | DEACT | 1 | 0 | 0 | 0 | 0 | 600 | 0 |E0|SU| SERVICE TELETYP |
+===+=======+=======+=====+====+=====+=====+=====+====+==+==+====================+
The value "DEACT" in the column "THRSHD1" shows that the minor alarm has been deactivated. Similarly, "DEACT" in the column "THRSHD2" shows that the major alarm has been deactivated. The value ’0’ in the column ’TIME’ shows that the single device alarm also is deactivated.
"ERR." corresponds to the number of errors found (actual). It is displayed as an absolute value and as a percent value.
"TOTAL" is the number of active units monitored by the dependabilit system under a specific alarm number
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.