207.5.2
CHANGE-VADSU
Changing the validation data of central, peripheral or logical alarms.
CHANGE-VADSU can be used to change threshold values and validation times. With directional or personal alarms, it can also be used to change the alarm name.
The threshold values of some central SWU alarms cannot be changed (see Table 1).
Procedure Overview
Command Code
Parameter
CHANGE-VADSU
ALARMGR=CENTRAL,ALARMNO=<number>
,{THRESHD1=<number>,THRESHD2=<number>
,TIME1=<number>,TIME2=<number>,TIME=<number>
,PRIO=<number>,HWCONT=<param>};
|ALARMGR=PERIPHER,ALARMNO=<number>
,{THRESHD1=<number>,THRESHD2=<number>
,TIME1=<number>,TIME2=<number>,TIME=<number>
,PRIO=<number>,HWCONT=<param>};
|ALARMGR=LOGICAL,ALARMNO=<number>
,{THRESHD1=<number>,THRESHD2=<number>
,TIME1=<number>,TIME2=<number>,TIME=<number>
,PRIO=<number>,HWCONT=<param>,NAME=<string>};
Example
Change the threshold value for the major alarm of central alarm 5.
Input:
CHANGE-VADSU:ALARMGR=CENTRAL,ALARMNO=5,THRESHD2=4;
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5