207.7.2
Advisories
H01:
ALARM NUMBER <ALARMNO> HAS BEEN ADDED.
H02:
MINOR ALARM <ALARMNO> HAS BEEN DEACTIVATED.
H03:
MAJOR ALARM <ALARMNO> HAS BEEN DEACTIVATED.
H04:
ALARM NUMBER <ALARMNO> HAS BEEN DELETED;
ANY ASSIGNMENTS TO THE FOLLOWING PENS HAVE BEEN CANCELED:
<gg-u-bbb-ss> <gg-u-bbb-ss> ...
H05:
ALARM NUMBER <ALARMNO> HAS BEEN DELETED;
ANY ASSIGNMENTS TO THE FOLLOWING STATION NUMBERS HAVE BEEN CANCELED:
<stno> <stno> ...
H06:
ALARM NUMBER <ALARMNO> HAS BEEN DELETED; THERE WERE NO ASSIGNMENTS.
H07:
NO ALARM PRESENT FOR THE SPECIFIED PARAMETERS.
H08:
NO ALARM ASSIGNMENTS PRESENT.
H09:
MINOR ALARM <ALARMNO> HAS BEEN ACTIVATED.
H10:
MAJOR ALARM <ALARMNO> HAS BEEN ACTIVATED.
H11:
AN ALARM INITIALIZED WITH ’DEACT’ CAN ONLY BE ACTIVATED USING ’CHANGE-VADSU’
H12:
EXPLANATION OF ALARM PRIORITY :
PRIORITY = 0 : ALARM MESSAGES FOR THIS ALARM GET THE MESSAGE PRIORITY DEFINED BY AMO-
SIGNL
(SEE A9000 TO A9007)
PRIORITY = 1 TO 8 : THIS PRIORITY IS USED AS MESSAGE PRIORITY FOR ALARM MESSAGES (SEE A9000 TO A9007) WHICH CONCERN THIS ALARM
PRIORITY = 9 TO 11 : SEE PRIORITY 0, BUT ADDITIONALLY :
(PRIORITY = 9 : ALARM MESSAGE OF THIS ALARM CLASS IS NOT SENT TO AFR1 (HTS)
(PRIORITY = 10 : ALARM MESSAGE OF THIS ALARM CLASS IS NOT SENT TO AFR2 (DMS))
(PRIORITY = 11 : ALARM MESSAGE OF THIS ALARM CLASS IS NOT SENT TO AFR1 (HTS) AND AFR2 (DMS))
H13:
ONLY THE ALARMS WHOSE HWCONT IS S1 ARE SIGNALIZED TO LED P2 (PAL) ON IOP AND NAL ON DP.FOR THIS HW-CONTACT THE SUMMARY SIGNALISATION (ALL MINOR ALARMS) IS DEACTIVATED. IT WILL ONLY BECOME ACTIVE AGAIN, WHEN HW-CONTACT = S1 FOR NO ALARM.
H14:
ONLY THE ALARMS WHOSE HWCONT IS S2 ARE SIGNALIZED TO LED C3 (ZAL) ON IOP AND UAL ON DP. FOR THIS HW-CONTACT THE SUMMARY SIGNALISATION (ALL MAJOR ALARMS) IS DEACTIVATED. IT WILL ONLY BECOME ACTIVE AGAIN, WHEN HW-CONTACT = S2 FOR NO ALARM.
H15:
THE SNAPSHOT FUNCTION IS ALREADY DEACTIVATED.