213.2.5
REGENERATE-VFGR
Procedure Overview
Command Code
Parameter
REGENERATE-VFGR
[ATNDGR=<number>];
Example
Regenerate ATNDGR 0.
Input:
REG-VFGR:ATNDGR=0;
Output:
ADD-VFGR:0,490,1,2,3,4,5,,,,1,,5,13,0&1&2&3&4&5&6&7&8&9&10&11&12&13&14&15,OFF,N ,Y,N,2;
CHANGE-VFGR:0,TYPE=PRIOCALL,3,3,2,2,4,5,5,5,5,2,2,2,2,2,2,5,2;
CHANGE-VFGR:0,TYPE=PRIOLEV,1,L2,3;
CHANGE-VFGR:0,TYPE=PRIOLEV,2,L1,3;
CHANGE-VFGR:0,TYPE=PRIOLEV,3,L1,1;
CHANGE-VFGR:0,TYPE=PRIOLEV,4,L1,2;
CHANGE-VFGR:0,TYPE=PRIOLEV,5,L2,2;
CHANGE-VFGR:0,TYPE=PRIOLEV,6&&48,L1,8;
If ITDEST is set for more than 16 values, then a new CHANGE-VFGR command is generated:
Input:
REG-VFGR:ATNDGR=62;
Output:
ADD-VFGR:62,DQ,13195
,1,,,,,,,,1,
,
10,1&2&3&4&5&6&7&8&9&10&11&12&13&14&15&16,OFF,NO
,YES,NO,,0,OFF,NO;
CHANGE-VFGR:62,
GENERAL,,,,,,,,,,,,,,17&18&19&20&21&22&23&24&25&26&27&
28&29&30&31;
OpenScape 4000 V10, Volume 1: AMO Descriptions, Service Documentation, Issue 5
, ID:
P31003H31A0S107057620
©
09/2025
Mitel Networks Corporation. - All rights reserved.