Collapse AllExpand All

17.8. BLOC - Signal "end-of-dial" to partner nodes Previous topic Parent topic Child topic Next topic

Feature:

Outgoing digital transmission to network

Function digital Trunks:

To ensure that the "Sending Complete" information element in a setup or information signal is transferred to the partner node, the parameter BLOC must be set in the COT of the trunk in which digital transmission takes place.
"Sending Complete" is only transmitted after the dialed digits reach the number of permitted digits to be transmitted for the specified route.

Function digital Trunks:

An "End of Dialing" Signal will be sent to the partner node. MFC-R2 use the Signal I-15 as EOD Signal. DTMF use # (hash; pound) as EOD signal.
"End of Dialing/EOD" is only transmitted after the dialed digits reach the number of permitted digits to be transmitted for the specified route.

AMO Interrelationships:

IMPORTANT:
The parameters TSCS and BLOC must be set in the COT for Q-Sig trunks.

Device types:

Digital CO trunk circuits, interface circuits and tie trunk circuits
For example, SOCOD, S2COD, SOCONN, S2CONN, etc.
Analogue trunk circuits, interface circuits and tie trunk circuits
For example, DIUCQ421, DIUCBRAZ etc.

Protocol variants:

CORNV33 - CorNet protocol
ECMA1 - ECMA QSIG V1 protocol
ECMA1R - ECMA QSIG V1 protocol
ECMAV2 - CorNet-NQ Issue 2.1 Dec. 96 Basic ETSI
ECMAV2R - QSIG ETSI ETS 300 172 3rd. with SS 2nd.
PSS1V2 - CorNet-NQ Issue 2.1 Dec. 96 Basic ISO/IEC
PSS1V2R - QSIG ISO ISO/IEC 11572 2nd. with SS
EDSGER - EDSS1 protocol for Germany
ETSI - Standard EURO-ISDN
EDSS1NET - EDSS1 Net Side protocol