Feature:
Call Data Recording Enhancements (CDRe)
Function:
COT parameter SNBE is used to control the forwarding of the billing information
element to the partner node.
If the parameter is activated in the COT of a trunk, then no billing information
element is sent to the partner system.
If the parameter is deactivated in the COT of a trunk, then the billing information
element is sent to the partner system.
Cost unit and control information for network-wide call data recording is transported
from
node to node in the billing information element.
The NOTRANS parameter is used to deactivate call data recording in all transit notes
of the route, only on the breakout trunk to CO a record is created.
If NOTRANS is used in the network SNBE must not be set.
IMPORTANT:
Do not set SNBE in conjunction with PINNW (PIN
network-wide). The parameter should always be set for digital tie trunk circuits and
interface circuits for Hicom 300 nodes less than Hicom 300 E V1.0.
AMO Interrelationships:
COT: IICB .... Ignore incoming billing information elements from a line
LDAT administration of LCR routes ... LATTR (LCR attribute)= ... NOTRANS
Device types:
Digital tie trunk circuits and interface circuits.
Protocol variants:
ECMAV2 (CorNet-NQ Issue 2.1 Dec.96 Basic ETSI), PSS1V2 (CorNet-NQ Issue 2.1 Dec.96
Basic
ISO/IEC)