Collapse AllExpand All

17.73. TCC - Signal incoming calls on analog tie trunk circuits as trunk calls Previous topic Parent topic Child topic Next topic

Feature:

Different terminal call signals

Function:

The TCC COT parameter can be used to control different call signals on analog tie trunk circuits of the type DB_CP_DEVTYP_TMA_CONN.
TCC set:
Terminals are called with the call type " co/extended call ring EXTCO" administered with the AMO ZAND.
TCC not set
Terminals are called with the call type "Standard ring NORM" administered with the AMO ZAND.

AMO Interrelationships:

ZAND: TYPE=RNGTYPE COEXT (co/extended call ring), NORM (standard ring)
TYPE=ALLDATA EXTCO (co/extended call ring also for switched calls and consultations from trunk calls)
FEASU: TYPE=FREE, LM=RNG Ring discrimination

Device types:

Analog tie trunk circuits type DB_CP_DEVTYP_TMA_CONN
For example, TSILP Tie trunk circuit, DC loop with idle signal loop

Protocol variants:

Analog