Feature:
Flag trace
Network-wide trace stop
Dynamic flag trace by means of digital analysis result (DAR) dialing
Function:
The flag trace allows a connection to be traced network wide in CP (Call Processing)
and DH
(Device Handler).
The COT parameter NOFT can be used to suppress the receiving and sending of flag trace
and
trace stop information on digital trunks.
Flag trace or trace stop information received on a trunk marked with NOFT leads to
the
immediate clearing of the incoming connection because it is like an attempted "tapping".
The digital analysis result DAR=FLTRACE, dynamic flag tracing network-wide is only
effective if the COT parameter <NOFT> is not set.
AMO Interrelationships:
TACSU, TDCSU, DPLN DAR=FLTRACE.... the digital analysis result "dynamic flag tracing"
can
be set up for both analog and digital trunks, TRACS
Device types:
Analog and networking trunks
Protocol variants: