Collapse AllExpand All

13.1.1. Assignment of Announcement Unit for General Text (internal) Previous topic Parent topic Child topic Next topic

  • Assign TMOM module
    AD-BCSU:MTYPE=PER,LTU=number,SLOT=number,
    PARTNO=string; 
    
  • Assign code for announcement unit (internal)
    AD-WABE:CD=key-num,DAR=ANSINT; 
    
  • Add class of trunk
    AD-COT:PAR=NTON; 
    
  • Add class of parameter
    AD-COP:PAR=SACK&LSUP;  
    
  • Add trunk group
    AD-BUEND:NO=number; 
    
  • Add trunk circuit
    AD-TSCSU:COTNO=number,TGRP=number,DEV=RA,
    COPNO=number,SUPV=SUPV2,ACKT=SZACK2; 
    
  • Assign a route to the announcement unit
    AD-RICHT:TYPE=CD,CD=key-num,SVC=VCE,TGRP1=number; 
    
  • Set timers (seconds)
    CHA-DTIM1:TYPEDH=TCOM,RATX= *.; 
    
    *) The time must be set so that it is twice as long as the announcement text. If several announcement units are used, the longest text must be used as a reference.