For transit lines:
In this case, the timer runs in the node with the exchange line
interface (originating node).
- Is the synchronized announcement configured in the originating node?
- For direct dialing to the a station user, the appropriate announcement types must
be entered for the SDOHK announcement reason in the ANNMITR table for the ITR number
of the calling exchange line.
- For callers who reach the station user via FWD/FNANS, the appropriate announcement
type must be entered for the ANNOHK announcement reason in the ANNMITR table for the
ITR number of the forwarding station. However, this only works for forwarding
stations in the same node as the announcement unit (e.g. originating node).
Otherwise, the ITR number of the exchange line applies.