Collapse AllExpand All

11.1.11.4. Generation (Example) Previous topic Parent topic Child topic Next topic

  • To enable or disable the feature the AMO ZAND is used:
    CHA-ZAND:TYPE=ATND,COD=<YES/NO>;
    
    If the feature is disabled a call always follows an existing diversion. The CoD buttons are without any function. The exception is if a loop subunit is reserved ('In Use' is displayed) and before the first digit is dialed, the reaction for the DES button is that 'NOT POSSIBLE is displayed.
  • If the feature in enabled, it can operated in 2 different operation modes, depending on the selection in AMO VFGR :
    CHA-VFGR:ATNDGR=<nr>,TYPE=GENERAL,COD=ON;
    
    With this setting the feature is enabled permanently. For each extension with a diversion (CFU or CFB) a decision to STEP or RING is necessary when it is requested. The DES button is without any function.
    CHA-VFGR:ATNDGR=<nr>,TYPE=GENERAL,COD=OFF;
    
    With this setting the feature is enabled temporary and the operator has to use the DES button to activate the feature for next call before dialing is started. Toggling is possible in this state. The information 'DES ACTIVE' is displayed or removed from the call control window. If the dialed extension has CFU or CFB activated, so the available information about the extension and diversion is displayed and the operator has to decide to follow (STEP button) or override (RING button) the diversion.