Collapse AllExpand All

11.2.2.1. Master Hunt Group Previous topic Parent topic Child topic Next topic

Subscriber number and hunt group number are the same. Subscriber can only be called as Attendant Light with 900.
  • Configure OpenStage device with busy lamp filed
    ADD-SBCSU:STNO=900,OPT=OPTI,CONN=DIR,
    PEN=1-25-2-0,DVCFIG=OPTIP500,TSI=1,COS1=23,
    COS2=9,LCOSV1=1,LCOSV2=1,LCOSD1=2,LCOSD2=2,DPLN=0,
    ITR=0,SSTNO=N,COSX=0,SPDI=10,SPDC1=0,IDCR=N,REP=0,
    STD=56,SECR=N,INS=Y,ALARMNO=0,RCBKB=N,RCBKNA=N,
    DSSTNA=N,DSSTNB=Y,DIGNODIS=N,CBKBMAX=5,HEADSET=N,
    HSKEY=NORMAL,CBKNAMB=Y,TEXTSEL=GERMAN,HMUSIC=0,
    COMGRP=0,BLF=Y;
    
  • Configure key layout for OpenStage device
    CHANGE-TAPRO:STNO=900,STD=65;
    
  • DSS key administration:
    ADD-ZIEL:TYPE=DSS,SRCNO=900,KYNO=1,DESTNOD=25501,
    DEV=AD1;
    
  • Configure Attendant Light device as a master in hunt group for getting a call queue:
    ADD-WABE:CD=900,DAR=STN;
    
    ADD-SA:TYP=TLN,RNR=900,VBZ=0,
    ART=LIN,ANOKAP=20,NAME="ATTENDANT LIGHT",
    VERLNEXT=NEIN,ANZART=SA;
    
  • Configure device as Attendant Light device
    CHANGE-SDAT:STNO=900,TYPE=ATTRIBUT,
    AATTR=ACLIGHT;