Collapse AllExpand All

11.6.2. CCM in Meet-me Operation Previous topic Parent topic Child topic Next topic

  • Assign codes for normal code calling, urgent code calling and answering in the DPLN
    AD-WABE:CD=key-num,DAR=CCMS; 
    
    AD-WABE:CD=key-num,DAR=CCMSURG; 
    
    AD-WABE:CD=key-num,DAR=CCMANS; 
    
  • Add configuration data for the TMOM module
    AD-BCSU:MTYPE=PER,LTU=number,SLOT=number,
    PARTNO=string; 
    
  • Assign a trunk group
    AD-BUEND:NO=number; 
    
  • The COT and COP parameters are entered as for DISPLAY operation, except that the COP parameter CCM for Meet-Me operation must also be specified.
  • The trunk circuit is assigned as for DISPLAY OPERATION except:
    SRCHATT = 5, default value (max. 99 possible) and OPTYPE=Meet-Me instead of DISPLAY.
  • Configure the circuit with the TSCSU AMO as for DISPLAY operation. The only parameters which are different are SRCHATT=5 (standard value, max. 99 possible) and OPTYPE=MEETME.
    For CCM in Meet-Me operation, the TSCSU parameter MABLK must be set to '0', i.e. calling party's number is not displayed (see also CCM in Meet-Me operation with Display).
  • Assign route to multiple code calling system
    AD-RICHT:TYPE=CD,CD=key-num,RTECD=key-num,
    SVC=VCE,TGRP1=number;