For CCM in DISPLAY operation, you can reverse the display sequence
of the number blocks on the CCM receiver devices by setting the ZAND
parameter AAFTERB. This means that the A-block will be displayed after
the B-block, i.e. the display sequence will be "answering number - calling
party's number - answering code" (B-block/A-block/C-block).
- Set new display sequence "answering number - calling party's number
- answering code"
CHA-ZAND:TYPE=CCM,AAFTERB;
Default Value: AAFTERB i s n o t set (i.e. standard
sequence A-block/B-block/C-block, i.e. "calling party's number -
answering number - answering code")
An answering code will only be displayed if assigned with the TSCSU
AMO.