Collapse AllExpand All

7.9.1. Feature description Previous topic Parent topic Child topic Next topic

12 or 16 kHz metering pulses are sent to analog stations with the classes of service "GET" and "Call charge metering pulse sending" or to coin boxes (new COS). The frequency of the metering pulses (depending on the time of day, type of day, zone, etc.) is either calculated by the OpenScape 4000 system (charge pulse metering) or received by a higher-ranking CO.
The OpenScape 4000 system supports the charge pulse types 16 kHz, 12 kHz, and line reversal.
A new SLMA board (SLMAR) was developed for sending the 12 kHz and 16 kHz pulses. The charge pulse types (16 KHz, 12 KHz, etc.) can be configured per port.
A special charge pulse is configured in the OpenScape 4000.
The pulse sending procedures listed below can be configured (see AMO GEFE / TTBL):
Fixed metering pulse sending at connection setup
One or more metering pulses are sent immediately as basic charges. Pulses are not sent periodically (interval set to 0).
Periodical metering pulse
One or more metering pulses are sent immediately. The pulses are then sent periodically according to the set intervals.
Periodical "Karlsson" (K) metering pulse
The first metering pulse is sent after a random period of time which lies within the configured interval range. The pulses are then sent periodically according to the set intervals. (Method 0)
Periodical "Karlsson added" (KA) metering pulse
The first metering pulse is sent immediately. The next metering pulse is sent after a random period of time which lies within the configured interval range. The pulses are then sent periodically according to the set intervals. (Method 1)
Periodical "Karlsson modified" (KM) metering pulse
The first metering pulse is sent immediately. The next metering pulse is sent after a random period of time which lies within a range of 2 times the configured interval. The pulses are then sent periodically according to the set intervals. (Method 2)