Fixed metering pulse sending at connection setup
|
One or more metering pulses are sent immediately
as basic charges. Pulses are not sent periodically (interval set to 0).
|
|
Periodical metering pulse
|
One or more metering pulses are sent immediately.
The pulses are then sent periodically according to the set intervals.
|
|
Periodical "Karlsson" (K) metering pulse
|
The first metering pulse is sent after a random
period of time which lies within the configured interval range. The pulses
are then sent periodically according to the set intervals. (Method 0)
|
|
Periodical "Karlsson added" (KA) metering pulse
|
The first metering pulse is sent immediately.
The next metering pulse is sent after a random period of time which lies
within the configured interval range. The pulses are then sent periodically
according to the set intervals. (Method 1)
|
|
Periodical "Karlsson modified" (KM) metering
pulse
|
The first metering pulse is sent immediately.
The next metering pulse is sent after a random period of time which lies
within a range of 2 times the configured interval. The pulses are then
sent periodically according to the set intervals. (Method 2)
|