Collapse AllExpand All

7.9.2.1. Charges for analog stations Previous topic Parent topic Child topic Next topic

The features "extended loop" and "Send metering pulse" are mutually exclusive.
The level is set with the AMO SCSU and is dependent on the station and line length.
The maximum line length is currently 300 m (approx.).
Metering pulses from the CO are converted on a one-to-one basis by the SLMAR.
Call charge information generated by the remote system is split by the CCUC parameter in the AMO ZAND and then forwarded as pulses by the SLMAR.
Separate clock tables must be configured with the AMO TTBL for internal and network-wide CDR by carrier and zone. Only the clock tables of the TTBL group are used for timer pulse generation. Clock tables in other groups are not analyzed by the software.