7.9.3.5. SCSU - Configuring an SLMAR station Previous topic Parent topic Child topic Next topic

ADD-SCSU:STNO=2250,PEN=1-2-67-
0,DVCFIG=ANATECM,DPLN=0,ITR=0,COS1=24,COS2=24,LCOSV1=7,LCOSV2=6,
LCOSD1=5,LCOSD2=4,CIRCDIX=1,DIAL=VAR,PULSTYPE=KHZ12,PULSLEV=VEFF
5;
  • DVCFIG ... Device configuration
    • ANATECM ... Analog station with metering
    • ANATE ... Analog telephone
  • CIRCIDX ... Index for timer block table
  • PULSTYPE ... Type of metering pulse
    • FORM ... Change pulse form
    • KHZ12 ... 12 kHz pulses
    • KHZ16 ... 16 kHz pulses
    • POL ... Polarity reversal
    • POL12 ... Polarity reversal + 12 KHz
    • POL16 ... Polarity reversal + 16 KHz
  • PULSLEV ... Level of metering pulses
    • VEFF5 ... 5 volts effective voltage
    Given that each station has a different line length and a different frequency separating filter, the setting for the pulse level and the pulse silent period in PTIME must be chosen carefully.
    When setting the metering level and the pulse length and duration, it is recommended that you have a measuring device for measuring the metering pulses as well as a data sheet for the frequency separating filter.