10.29. Entrance Telephone with Door Opener Previous topic Parent topic Child topic Next topic

  • Add the configuration of the TMOM module
    AD-BCSU:MTYPE=PER,LTU=number,SLOT=number,
    PARTNO=string; 
    
  • Assign codes for the entrance telephone and door opener in the DPLN
    AD-WABE:CD=key-num,DAR=DOORCL&TORAUF; 
    
  • Assign a class of trunk
    AD-COT:PAR=NTON; 
    
  • Assign a class of parameter
    AD-COP:PAR=LSUP; 
    
  • Add trunk group
    AD-BUEND:NO=number; 
    
  • Add trunk circuit
    AD-TSCSU:COTNO=number,DEV=DOOR,COPNO=number; 
    
  • Assign a route to the entrance telephone for DOORCL and DOOROPEN
    AD-RICHT:TYPE=CD,CD=key-num,