Collapse AllExpand All

14.4.6.2.1. TMDNH for T1 BOS EMW TIE Previous topic Parent topic Child topic Next topic

  1. CHANGE-LWPAR:TYPE=TMD,TMDTYPE=TMDBOS,BLNO=1,
    OPMODE=FRAMEESF&BISUB8ON&BDETON&NETUSER,
    CABLETYP=1,OESDISTH=30,OESREQTH=4,SESDISTH=10,
    SESREQTH=10;
     
    ADD-BCSU:MTYPE=TMD,LTG=1,LTU=2,SLOT=49,
    PARTNO="Q2192-X",FCTID=1,LWVAR="K",LWPAR=1,
    FIDX=1,HWYBDL=A;
    
    ADD-COSSU:NEWCOS=220,AVCE=TA&TNOTCR&CDRC;
    
    The following section is for EMW protocol (with pulse dialing trunk group 242 Dial-Number 542 for TIE ( IWV- Pulse Rotary EMW protocol) as an example).
    ADD-WABE:CD=542,DAR=TIE;
     
    ADD-BUEND:TGRP=242,NAME="T1EMWIWV",NO=2;
    
    COT and COP for Wink-DIAL IWV
    ADD-COP:COPNO=242,PAR=ANS&RLSA&BR64&TIM1&
    IDP1&SDL&SFRM&NAAT,INFO="QS-EMW-IWV";
     
    ADD-COT:COTNO=242,PAR=RCL&NTON&ANS&NAAT&CEBC,
    INFO=QS-EMW-IWV;
     
    ADD-TACSU:PEN=1-2-49-1,COTNO=242,COPNO=242,
    COS=220,LCOSV=1,LCOSD=1,TGRP=242,CCT="QSGUS-IM",
    INS=Y,DEVTYPE=TT,DEV=T1EMW;
     
    ADD-TACSU:PEN=1-2-49-2,COTNO=242,COPNO=242,
    COS=220,LCOSV=1,LCOSD=1,TGRP=242,CCT="QSGUS-IM",
    INS=Y,DEVTYPE=TT,DEV=T1EMW;
    
    ADD-RICHT:MODE=LRTENEW,LRTE=242,LSVC=VCE,
    NAME="T1EMW",TGRP=242,DNNO=1-1-501,ROUTATT=NO,
    INFO="T1EMW",PDNNO=0;
    
    ADD-LDAT:LROUTE=242,LSVC=VCE,LVAL=1,TGRP=242,
    ODR=2,LAUTH=1;ADD-LDPLN:LCRCONF=LCRPATT,
    DIPLNUM=0,LDP=542-X,LROUTE=242,LAUTH=1;
    
    The following section is for EMW protocol with DTMF dialing trunk group 243
    ADD-WABE:CD=543,DAR=TIE;
     
    ADD-BUEND:TGRP=243,NAME="T1EMWMFV",NO=2;
     
    ADD-COP:COPNO=243,PAR=ANS&RLSA&DTMF&DTM1&
    TIM1&SDL&SFRM&NAAT&PDP1,TRK=TA,TOLL=TA,
    DEV=INDEP,INFO=QS-WINK-MFV;
     
    ADD-COT:COTNO=243,PAR=RCL&NTON&ANS&
    NAAT&CEBC,INFO=QS-WINK-MFV;
     
    ADD-TACSU:PEN=1-2-49-5,COTNO=243,COPNO=243,
    COS=220,LCOSV=1,LCOSD=1,TGRP=243,CCT="QSGUS-IM",
    INS=Y,DEVTYPE=TT,DEV=T1EMW;
     
    ADD-TACSU:PEN=1-2-49-6,COTNO=243,COPNO=243,
    COS=220,LCOSV=1,LCOSD=1,TGRP=243,CCT="QSGUS-IM",
    INS=Y,DEVTYPE=TT,DEV=T1EMW;
     
    ADD-RICHT:MODE=LRTENEW,LRTE=243,LSVC=VCE,
    NAME="T1EMW",TGRP=243,DNNO=1-1-501,ROUTATT=NO,
    INFO="T1EMIMFV",PDNNO=0;
     
    ADD-LDAT:LROUTE=243,LSVC=VCE,LVAL=1,TGRP=243,
    ODR=2,LAUTH=1;
     
    ADD-LDPLN:LCRCONF=LCRPATT,DIPLNUM=0,LDP=543-X,
    LROUTE=243,LAUTH=1;