5.3.3.2.1. With Privileged Station AMO SSC Previous topic Parent topic Child topic Next topic

  • The COP parameter ANNC (local recorded announcement) is to be set in the incoming circuit. A configured local recorded announcement is then created for the incoming seizure. The COP parameters DTN (incoming seizure dial tone) and ANNC are mutually exclusive.
  • If the system is to use a predefined recorded announcement or music, the local recorded announcements must be assigned the desired value in AMO ZAND:TYPE=TONES.
  • If an external recorded announcement device is to be used, a privileged station must be configured with the AMO SSC with the TYPE=EXTANN and the CPCALL=LOCANN. The external recorded announcement device is connected to this privileged station.