For outgoing seizable circuits or ports (TMC16/T1Loop Ground) which
are triggered on account of a fault (e.g. no incoming circuit seizable
or no audible signal) and enter disabled state, another circuit can be
searched in the same trunk group and seized, or if there is no trunk
available in the same trunk group,searched in a different trunk group
and seized via trunk group overflow (Rerouting) without having to dial
again.
To this end, it is necessary to configure another trunk group with
circuits, in addition to the trunk group originally used.
The original and additional trunk group numbers must be specified
in AMO RICHT. Furthermore, the parameter REROUTING must be set to YES,
also the parameter RERINGRP (Rerouting in the same trunk-group) must
be set to YES
The AMO LDAT with its original LCR number must be reconfigured with
the additional trunk group number.
Example: