Collapse AllExpand All

5.5.3.6. Switching the Tie Trunk Circuits On and Off Previous topic Parent topic Child topic Next topic

When switching off tie trunk circuits (analog or digital), the AMO DSSU (regardless of the parameter OFFTYPE) leaves the line marking unchanged. In contrast, when switching on or restarting a tie trunk circuit with the following properties (regardless of the parameter ONTYPE), the line marking is set for all configured B-channel groups:
  • The tie trunk circuit must be assigned the CorNet-NQ protocol (AMO TDCSU, parameter PROTVAR))
  • The CorNet-NQ protocol must be configured with Segmentation 8 (AMO TDCSU, parameter SEGMENT)
  • The Polling Timer must be configured (AMO ZAND, parameter NWTOPTIM > 0)
This results in the automatic detection of the partner node being started faster when the feature is activated.
The AMO TDCSU, which likewise switches circuits off and on, acts in exactly the same way as described previously for the AMO DSSU.