The AMO LWCMD can be used to send so called 'EXECUTE' commands
to the loadware and display the response data (e.g. dump data) at the
OpenScape 4000 service terminal. The 'EXECUTE' commands are
described in a separate document.
EXEC-LWCMD:LTU=1,SLOT=67,TYPE=CDG,CMD="... here enter EXECUTE
cmd ...",TIMER=30;
The AMO supervise timer is set in this example to 30 seconds. The
EXECUTE command is passed transparently to LW and if it is coupled with
response data, data are displayed in ASCII format.