CorNet-VN will run on the TMDNH (Q2192-X, Function ID 3) card or on
its replacement DIUN2U (Q2216-X, Function ID 6).
- How to configures the TMDNH / DIU2U board
configures the TMDNH board:
ADD-BCSU: MTYPE=TMD, LTG=x, LTU=y, SLOT=z, PARTNO="Q2192-X",
FCTID=3, LWVAR="K", HWYBDL=A;
configures the DIU2U board:
ADD-BCSU: MTYPE=TMD, LTG=x, LTU=y, SLOT=z, PARTNO="Q2216-X",
FCTID=6, LWVAR="K", HWYBDL=A;
- How to configures the CorNet-VN AT&T
The following commands are based on COPY-PRODE: TYPE=PVCD, PVCDNO=16
to load the US protocols into memory (default PVCDNO = 16). Then the
associated PRODE tables for CVN1 and CVN2 are available.
configures the AT&T trunk:
CHANGE-LWPAR: TYPE=TMD, TMDTYPE=TMDMOS, BLNO=3,
OPMODE=FRAMEESF&BISUB8ON&BDETON, CABLETYP=1, OESDISTH=30,
OESREQTH=4, SESDISTH=10, SESREQTH=10, ACKTIM=10, DLVTIM=300,
OCTMAX=260, RETMAX=3, WINDOW=7, CRIDC=0288, NSFIV=1,
NSFTSC=9, TTSC=4;
configures new device S1CVN with AT&T protocol:
ADD-TDCSU: OPT=NEW, PEN=x-y-z-1, COTNO=99, COPNO=95, DPLN=1,
ITR=0, LCOSV=1, LCOSD=1, CCT=" ", DESTNO=5, PROTVAR="CVN1",
SEGMENT=1, DEDSVC=NONE ,TRTBL=GDTR, SIDANI=N, ATNTYP=TIE,
CBMATTR=NONE, TCHARG=N, SUPPRESS=0, TRACOUNT=31,
SATCOUNT=MANY, NNO=1-1-501, ALARMNO=2, FIDX=1, CARRIER=1,
ZONE=EMPTY, COTX=99, FWDX=1, CHIMAP=N, UUSCCX=16, UUSCCY=8,
FNIDX=1, NWMUXTIM=10, CLASSMRK=EC&G711&G729OPT, TGRP=98,
SRCHMODE=DSC, INS=Y, DEV=S1CVN, BCHAN=1&&23, BCNEG=N, BCGR=1,
LWPAR=3;
- How to configures the CorNet-VN MCI trunk
The following commands are based on COPY-PRODE: TYPE=PVCD, PVCDNO=16
to load the US protocols into memory (default PVCDNO = 16). Then the
associated PRODE tables for CVN1 and CVN2 are available.
configures the MCI trunk:
CHANGE-LWPAR: TYP=TMD, TMDTYP=TMDMOS, BLNO=4,
OPMODE=FRAMEESF&BISUB8ON&BDETON, CABLETYP=1, OESDISTH=30,
OESREQTH=4, SESDISTH=10, SESREQTH=10, ACKTIM=10, DLVTIM=300,
OCTMAX=260, RETMAX=3, WINDOW=7, CRIDC=0222, NSFIV=1,
NSFTSC=9, TTSC=4
configures new device S1CVN with MCI protocol:
ADD-TDCSU: OPT=NEW, PEN=x-y-z-1, COTNO=99, COPNO=95, DPLN=1,
ITR=0, LCOSV=1, LCOSD=1, CCT=" ", DESTNO=5, PROTVAR="CVN2",
SEGMENT=1, DEDSVC=NONE ,TRTBL=GDTR, SIDANI=N, ATNTYP=TIE,
CBMATTR=NONE, TCHARG=N, SUPPRESS=0, TRACOUNT=31,
SATCOUNT=MANY, NNO=1-1-501, ALARMNO=2, FIDX=1, CARRIER=1,
ZONE=EMPTY, COTX=99, FWDX=1, CHIMAP=N, UUSCCX=16, UUSCCY=8,
FNIDX=1, NWMUXTIM=10, CLASSMRK=EC&G711&G729OPT, TGRP=98,
SRCHMODE=DSC, INS=Y, DEV=S1CVN, BCHAN=1&&23, BCNEG=N, BCGR=1,
LWPAR=4;
- Activation / Deactivation of CorNet-VN
displays the number of contracted, assigned and free CVN trunks:
DISP-CODEW;