5.14.8. Callback Previous topic Parent topic Child topic Next topic

Callback if busy between station users of a private network Callback if busy from and to public ISDN users Callback on no answer between users in a private network (not VFSS)
  • The parameter CBK must be declared in the AMO DIMSU
    AD-DIMSU:TYPE=USER,CBK=number; 
    
  • For callback throughout the network the AMO COT has two parameters: CBBN for callback if busy, and CCFN for callback on no answer.
    AD-COT:COTNO=number,PAR=CBBN; 
    
    AD-COT:COTNO=number,PAR=CBFN; 
    
    IMPORTANT:
    Line circuits must be hard-blocked, since the Call References are not deleted with a soft block, and the circuit only becomes free when all its callback jobs have been processed.
    IMPORTANT:
    Der COT parameter TSCS is to be set on all digital circuits (tie/public).