OpenScape 4000 supports the connection of NI BRI applications and data devices via an OptiPoint telephone as follows:
  1. A 2B + D interface that is provided by an ISDN application in a PC, which in turn is connected to the USB port of an OptiPoint telephone; see FDBs for the feature ID 5073 for information on NI BRI support via the USB interface: API (TAPI / CAPI) for OptiPoint telephone.
  2. Maximum of two NI BRI data devices with S interface. As an exception to the SLMO card "3-device rule", an additional analog device (for example, a telephone or fax device) on each NI BRI data device that is connected to the TA S0 terminal adapter in an OptiPoint telephone in which no other TAs are installed. 
  3. An NI BRI data device with S interface that is connected to an TA S0 terminal adapter in an OptiPoint telephone in which a TA t/r terminal adapter is also installed.