Collapse AllExpand All

5.24.4. Generation Previous topic Parent topic Child topic Next topic

  • How to add the T1 board:
    COPY-PRODE:TYPE=PVCD,PVCDNO=16; 
    /*loads the US protocols into memory
     
    ADD-BCSU:MTYPE=TMD,LTG=1,LTU=1,SLOT=43,PARTNO="Q2192-X",FCTID=2,
    LWVAR="K", HWYBDL=A; /*configures T1 board
     
    CHANGE-LWPAR:TYPE=TMD,TMDTYPE=TMDMOS,BLNO=2,OPMODE=FRAMEESF&BISUB8ON&BDETON,
    CABLETYP=1,OESDISTH=30,OESREQTH=4,SESDISTH=10,SESREQTH=10,ACKTIM=10,
    DLVTIM=600,OCTMAX=260,RETMAX=3,WINDOW=7; /
    *loadware parameters for T1 board
    
  • How to setup the trunk for NI2 without a dedicated calling service
    ADD-COT:COTNO=100,PAR=IIDL&IVAC&INAU&ITB&IDND&IFR&ANS&CEOC&
    CEBC&COTN&IEVT&IDIS&LWNC&NLCR&ICZL&NCT&NTON;
     
    ADD-COP:COPNO=100,PAR=SDL&BR64&RMSG&RRST&TIM1&IDP4;
     
    ADD-TDCSU:OPT=NEW,PEN=1-01-043-0,COTNO=100,COPNO=100,COS=1,LCOSV=9,LCOSD=9,
    CCT="PRI",DESTNO=0,PROTVAR=NI2,SEGMENT=1,DGTPR=1,ISDNIP=561,ISDNNP=923,
    PNPL2P=011,PNPL1P=1,NNO=1-1-99,TGRP=104,SRCHMODE=ASC,DEV=S1COD,BCHAN=1&&23,
    BCNEG=N,BCGR=1,IGN=1,IID=1,LWPAR=6,LWPP=2;