Collapse AllExpand All

2.5.2.1. Analog Line Circuits Previous topic Parent topic Child topic Next topic

  • Add the module configuration data (peripheral line module):
    AD-BCSU:MTYPE=PER,LTU=number,SLOT=number,PARTNO=string,
    [LWVAR=string];
    
    IMPORTANT:
    As a rule, line modules are loaded with the loadware for Germany. Some modules, however, require different loadware variants in order to comply with PTT requirements in foreign countries (e.g. SLMA Q2141-X). The parameter 'LWVAR' can be used in order to specify the required loadware variant when the modules are configured. For a list of possible loadware variants for each module, please consult the appropriate module description. Once the module has been configured, the loadware variant can be changed with the AMO ZAND.
  • Assign a class of service:
    AD-COSSU:AVCE=param; 
    
  • Assign a class of parameter (device handler parameters):
    AD-COP:PAR=param; 
    
  • Assign a class of trunk
    AD-COT:PAR=param; 
    
  • Lines for incoming traffic only are normally not assigned to trunk groups.
  • Assign an analog line circuit:
    AD-TACSU:PEN=pen,COTNO=number,COPNO=number,LCOSV=number,
    LCOSD=number, DEVTYPE=<circuit_type>,DEV=<circuit_type>;