Collapse AllExpand All

10.25.3. Service Information Previous topic Parent topic Child topic Next topic

  • DSS 1 terminals should always be configured for the VOICE&FAX & DATA services.
  • If a busy DSS1 terminal is called by a system terminal, the ringing tone is injected first, followed by the busy tone.
  • The COS of the terminals must include the MULTRA parameter. Otherwise, the new services cannot be used.
  • Calls on hold are released when the holding party goes on-hook. There is no recall.
  • A separate buffer for FWD must be generated in DIMSU AMO. Dimension the buffer as follows: number of DSS1 terminals x 3.
  • In ZAND AMO, the OPTLOAD table must be adjusted (development).
  • The maximum number of callbacks is set in SBCSU AMO.
  • New COS are implemented in AMO COSSU.
  • If the MULTRA parameter is set, a DSS1 terminal can no longer be used in a hunting group.
  • The secretary function is not implemented.
  • Changes to the AMO surface.
  • COSSU parameters for CCBS and Call Waiting.
  • New branch for FWDDSS1 (AMO ZIEL).
  • Transfer by release is not possible (separate function).
  • Callback from a system terminal is possible with restrictions.
  • COLR to a system terminal is not possible.
  • DSS1 terminal can call itself: no
  • If on a Profiset50 a 4-digit number is displayed without a name, the first digit ­disappears after a brief period of time.
  • The feature groupcall in AUN-Group is not possible for DSS1 terminals.
  • DSS1 terminals cannot dial the code for PSE (paging equipment)