10.41.3. Transmission Range Previous topic Parent topic Child topic Next topic

Table 59. Transmission range OpenStage T (0,6 mm cable)

Phone
Transmission range
[dB]
Feeding range for 0,6 mm cable
Pmax
[W]
U (OpenScape 4000) = 42V
U (OpenScape 4000) = 48V
Rcab
[Ohm]
range
[m]
Rcab
[Ohm]
range
[m]
OpenStage 10 T
16
1,5
234
1800
312
2400
OpenStage 20 T
16
1,5
234
1800
312
2400
OpenStage 40 T
16
2,3
130
1000
195
1500
OpenStage 60/80 T
16
2,2
143
1100
221
1700

Table 60. Transmission range OpenStage T (0,8 mmm cable)

Phone
Transmission range
[dB]
Feeding range for 0,8 mm cable
Pmax
[W]
U (OpenScape 4000) = 42V
U (OpenScape 4000) = 48V
Rcab
[Ohm]
range
[m]
Rcab
[Ohm]
range
[m]
OpenStage 10 T
16
1,5
234
3100
312
4200
OpenStage 20 T
16
1,5
234
3100
312
4200
OpenStage 40 T
16
2,3
130
1700
195
2600
OpenStage 60/80 T
16
2,2
143
1900
221
3000

Notes:

  1. The actual range depends on the characteristics of the used cable (loss, diameter).
  2. The maximum range is the minimum value of transmission range and feeding range.
  3. If a local power supply is used, the feeding range is not relevant.
  4. For transmisson ranges of different cable types please refer to Table 63, "Transmission range - cable types and their characteristics" (column 16dB).

Table 61. Transmission range - cable types and their characteristics

Cable type
Cable values
maximum range [m]
Delay
Loss
RLoop
Delay
Loss
[μs/km]
[dB/km]
[Ohm/km]
20,8 μs
16 dB
14,5 dB
J-2Y(ST)Y4x2x0,51 LG ICCS Data5
6,3
9,1
185
3300
1700
1500
J-2YY ...x2x0,6/1,4 VIMF FR ICCS
6,3
9,1
130
3300
1700
1500
J-02YSCY4x2x0,5 PIMF ICCS300S
5,5
9,4
190
3800
1700
1500
J-02YS(ST)CY4x2x0,55 PIMF ICCS Data6
5,5
8,8
164
3800
1800
1600
J-2Y(ST)Y < 10x2x0,6 STIIIBD
6,3
10,8
130
3300
1400
1300
J-2Y(ST)Y > = 10x2x0,6 STIIIBD
6,3
8,8
130
3300
2100
1900
J-2Y(ST)Y < 10x2x0,8 STIIIBD
6,3
n.v.(1)
73,2
3300
J-2Y(ST)Y >= 10x2x0,8 STIIIBD
6,3
73,2
3300
Installation cable < 10x2x0,6 (2)
8
15,6
130
2600
1000
900
Installation cable >= 10x2x0,6 (2)
8
11
130
2600
1400
1300
Installation cable < 10x2x0,8 (2)
8
14
73,2
2600
1100
1000
Installation cable >= 10x2x0,8 (2)
8
8
73,2
2600
2000
1800
Outdoor cable < 10x2x0,6 STIIIBD (2)
6,3
9,6
130
3300
1600
1400
Outdoor cable >= 10x2x0,6 STIIIBD (2)
6,3
7,4
130
3300
2100
1900
Outdoor cable < 10x2x0,8 STIIIBD (2)
6,3
73,2
3300
Outdoor cable >= 10x2x0,8 STIIIBD (2)
6,3
6,1
73,2
3300
Outdoor cable ...x2x0,4 (3)
6,3
10,5
300
3300
1500
1300
A-PM ...x2x0,6 STIIILG or BD (3)
5,5
6
130
3800
2600
2400
A-PM ...x2x0,8 STIIILG (3)
5,5
4,5
73,2
3800
3500
3200
Examples for installation cables:
  • J-Y(ST)Y Nx2x0,6/0,8 LG
  • J-YY Nx2x0,6/0,8 BD
  • J-H(ST) H Nx2x0,6/0,8 BD FR NC
  • JE-H(ST) H Nx2x0,8 BD FRNCX
Examples for outdoor cables:
  • A-2Y(L) 2Y Nx2x0,4/0,6/0,8 ST III BD 1PPERF
  • A-2YF(L) 2Y Nx2x0,4/0,6/0,8 ST III BD
  • A-2Y0F(L)2Y Nx2x0,6/0,8 ST III BD
  • A-02YS0F(L)2Y Nx2x0,6/0,8 ST III BD

 (1) n.v. = no values available
 (2) see examples below