Collapse AllExpand All

10.53.2.7. Station Controlled Conference in the Private Network Previous topic Parent topic Child topic Next topic

When the local and remote nodes have a linked conference connection established:
  • The user interface can operate as two independent conferences. Therefore, members in each independent conference can be able to scroll through their respective conference members (local to their node) and see the party they are linked to in the remote switch
When a conference is established in one node with a "single station" across CorNet:
  • From the "single station's" point of view the following happens:
    • The CONFERENCE key LED of the single station doesn't light unless a local conference is established in the single station node, which includes that station.
    • When brought into the remote conference the single station gets a display "CONFERENCE" as indication that they are connected to a remote conference.
    • The single party station node shall not inject music into the remote conference when placing the remote conference on soft or hard hold. See AMO-COT information in Section 143.5, "Relevant AMOs" for additional information in situations where the single party's node does not signal hold.
    • The single station shall be able to initiate all local features they could initiate when active in a two party connection in their node, with some exceptions:
      The single station cannot do transfer by pull when consulted across the NW by a conference member
      The single station cannot do transfer ringing or transfer busy when consulting away from the conference connection.
      The single station cannot park the conference connection, since pickup of a conference connection is not allowed.
  • From the remote conference point of view the following shall happen:
    • The remote conference members shall have access to all conference features local to their node.
    • The remote conference members display shall display the single station's name and private number information.
    • The remote conference members' display shall not be updated if the single station creates a conference or is brought into a conference local to the single party node.
    • The remote conference members display shall be updated if the CorNet link between the single station and remote conference is disconnected or if the conference established at the single station node is disconnected.