10.56.2. Flashing Signal at AC Previous topic Parent topic Child topic Next topic

Digit analysis result OUTPULSE

The digit analysis result OUTPULSE is designed to send digits, in this case for "flashing signal at AC" on the EB5 system. The only call progress state permitted is consultation hold (CPS 9).
  • You can configure the code for flashing in the AMO WABE as follows:
    ADD-WABE:STNO=x,CPS=9,DAR=OUTPULSE; 
    

Line circuit parameter FLAC

EB5/NAL line circuits reserved for external transit traffic must be released for flashing in the class of trunk (COT) with the line circuit parameter FLAC. The line circuit parameter FLAC may not be set for tie trunk traffic.
  • You can expand the class of trunk for flashing as follows:
    CHA-COT:COTNO=x,COTTYPE=COTADD,PAR=FLAC;