Collapse AllExpand All

10.59.4.1. LED Handling Previous topic Parent topic Child topic Next topic

  • The following settings are required in order to receive the correct LED cadences for US installations.
    CHANGE-ZAND:TYPE=LEDTYPE,RINGING=MEDIUM;
    
    CHANGE-ZAND:TYPE=LEDTYPE,HELD=WINK;
    
    CHANGE-ZAND:TYPE=LEDTYPE,CALLFWD=VERYFAST;
    
    CHANGE-ZAND:TYPE=LEDTYPE,FEATURE=MEDIUM;
    
    CHANGE-ZAND:TYPE=LEDTYPE,PRIORITY=VERYFAST;
    
    The following tables show the relationship between the database, the amo parameters, and the actual cadences.

    Table 63. Default Initialisation of LEDs for I.M

    LED Function
    RATE
    LED
    CADENCE
       
    ON(ms)
    OFF(ms)
    Feature DB_LED_OP_BLINKEN_LANGSAM)
    SLOW
    750
    750
    Priority DB_LED_OP_BLINKEN_SCHNELL )
    FAST
    250
    250
    Ringing DB_LED_OP_RING
    FAST
    250
    250
    Held DB_LED_OP_RING
    SLOW
    750
    750
    Callfwd DB_LED_OP_CALL_FORWARD
    OFF
    0
    100

    Table 64. Settings required for U.S. Market

    LED Function
    RATE
    LED
    CADENCE
       
    ON(ms)
    OFF(ms)
    Feature DB_LED_OP_BLINKEN_LANGSAM)
    MEDIUM
    500
    500
    Priority DB_LED_OP_BLINKEN_SCHNELL )
    VERYFAST
    50
    50
    Ringing DB_LED_OP_RING
    MEDIUM
    500
    500
    Held DB_LED_OP_HELD
    WINK
    450
    50
    Callfwd DB_LED_OP_CALL_FORWARD
    VERYFAST
    50
    50