Collapse AllExpand All

10.20. Digital Station with S0 Interface Previous topic Parent topic Child topic Next topic

Bus configurations can be set up with various devices at the S0 interface (STMD or STHC and STMD2) with PNT-E (SLMO24, SLMOP, STHC, etc.).

Device types

  • Functional terminals are operated with the protocols SBDSS1 or SBNIBRI.
You can connect up to three devices with different services and protocols but a single call number to the S0 bus. Only one protocol is permitted per service.
The introduction of MSN call numbers lets you extend the number of call numbers at the S0 bus beyond the above limits (only applies to functional terminals and therefore not to all other types of configuration described below - see also chapter "EURO ISDN Terminals", Section 120.2.1, "Multiple Subscriber Numbers (MSN) on the S0 Bus".
You can configure the following connection options:
  • direct
  • over PNT E (Private Network Terminator) at the Up0/E or ANSI-U NTBA
  • as an "external" extension only at STMD (over public paths)

Configuration types