27.4
Error Messages and Advisories
27.4.1
Error Messages
F01:
LTG HAS NOT BEEN ASSIGNED
F02:
LTU HAS NOT BEEN ASSIGNED
F03:
MODULE CODE NUMBER OR FUNCTION ID INVALID !
FOR BOARDS WITH MORE FUNCTIONS THE AMO HAS TO INVESTIGATE THE BOARD DATA
BY THE COMBINATION OF PARTNO AND FCTID. IF THE FCTID IS NOT SPECIFIED THE
DEFAULT VALUE 0 FOR THIS PARAMETER MIGHT NOT LEAD TO VALID BOARD DATA.
PROBABLY THE WRONG CONFIGURATION/DECONFIGURATION BRANCH IS USED !
F04:
MOUNTING SLOT n INVALID
F05:
MOUNTING SLOT ASSIGNED
F06:
MODULE AT THIS MOUNTING SLOT INVALID
F07:
ERROR AT ADD/DELETE WAML1 BOARD
A WAML1 BOARD HAS ALREADY BEEN ADDED or
FOR FURTHER WAML1 THE FLEXAMA MEMORY HAS TO BE INCREASED (AMO-DIMSU) or
THE MEMORY FOR WAML1 BOARD HAS TO BE ASSIGNED BY AMO-DIMSU FIRST or
AT SPECIFIED PEN NO DATA FOR WAML1 COULD BE FOUND or
CONFIGURATION ON WAML1 BOARD STILL EXISTS ==> DELETE WITH AMO-LANC
F08:
MOUNTING SLOT NOT ASSIGNED
F09:
NO DIUC CONNECTED AT SPECIFIED PEN (aa, bb, ccc)
F10:
MODULE LINE CIRCUITS NOT DELETED
F11:
LOADING SUBSYSTEM "UBGDAT00" NOT POSSIBLE
F12:
MOUNTING SLOT INVALID -
MODULE REQUIRES @ FREE MOUNTING LOCATIONS
F13:
FOR LTU n (shelftype - SHELF) THE SPECIFIED BOARD IS NOT ALLOWED
TO BE CONFIGURED
shelftype = NORMAL, COMPACT, EXT_COMP_X, 80CM_BASE, CC80X, CC80F,
40CMX_BASE, INCH19, AP37009 or AP370013
F14:
IN THIS LTU SHELF NO SIUP BOARD IS ALLOWED TO BE ADDED
F15:
DATA BASE INCONSISTENT (NO LOADFILES ENTERED)
F16:
IN A MODULAR CABINET SYSTEM SHELF, ONLY RG, ACGEN AND SIUP
MODULES MAY BE CONFIGURED AT SLOT 19
F17:
ANOTHER MODULE HAS BEEN ASSIGNED AT THE MOUNTING SLOT
F18:
PART NUMBER DOES NOT LEAD TO A PERIPHERAL SIU BOARD
F19:
MOUNTING SLOT n WILL NOT BE PROCESSED
F20:
MODULE TYPE AT THIS MOUNTING SLOT WILL NOT BE PROCESSED
F21:
NOT POSSIBLE TO ASSIGN A SIUP IN THE SPECIFIED LTU QUARTER BECAUSE
THERE IS ALREADY A PERIPHERAL SIU BOARD ASSIGNED.
F22:
not applicable anymore
F23:
VALUE OUT OF RANGE
F24:
IN THIS CASE PARAMETER MUST BE ANSWERED
F25:
AMO IS ALREADY RUNNING - FURTHER START NOT PERMITTED
F26:
THE PERMITTED NUMBER OF MODULE TYPES HAS ALREADY BEEN ASSIGNED
F27:
THE DESIRED BOARD CHANGE IS NOT ALLOWED !
POSSIBLE REASONS :
- BOARD TYPES DON'T MATCH
- BOARD CHANGE EXPLICITELY RESTRICTED (E.G. LAYOUT DIFFERS)
- COMBINATION OF SACHNR1/FCTID1 DOESN'T MATCH CONFIGURED BOARD
- COMBINATION OF SACHNR/FCTID (DEFAULT=0) NOT FOUND IN UBGDAT
- COMBINATION OF SACHNR1/FCTID1 NOT CHANGEABLE AGAINST SACHNR2/FCTID2
(LINE-TYPE DOESN'T MATCH)
- LINE RANGE OF BOTH BOARDS DON'T MATCH
(STMIX DOES NOT SUPPORT WAML FUNCTION)
F28:
not applicable anymore
F29:
REQUIRED TIMESLOTS FOR SIUP ARE USED BY FOLLOWING ACTIVE
VOICE COMPRESSION CONNECTIONS :
PEN : ltg-ltu-slot VCSU n (message is displayed n times)
DEACTIVATE THESE VC CONNECTIONS WITH AMO-VOICO FIRST
F30:
MODULE LINE CIRCUIT IS ENTERED IN THE REFERENCE CLOCK LIST -
DELETE ENTRY WITH AMO "REFTA"
F31:
THE BOARD CANNOT BE DELETED BECAUSE IT IS STILL MEMBER OF
HFA BOARD RECONFIGURATION POOL @@@@@.
PLEASE REMOVE IT FROM THE POOL BY MEANS OF AMO-BPOOL FIRST.
F32:
THE BOARD CHANGE CAUSES ALSO A REDUCTION OF AVAILABLE LINE CIRCUITS.
SOME MODULE LINE CIRCUITS ARE NOT DELETED IN THE OBSOLETE RANGE - THOSE
LINE CIRCUITS HAVE TO BE DELETED FIRST.
F33:
LOADWARE WITH SPECIFIED VARIANT NOT PRESENT ON HARDDISK
F34:
FOR SIUX BOARD THE PARAMETER FCTID IS MANDATORY
POSSIBLE VALUES ARE : 2 ... SIU_TYPE_2
3 ... SIU_TYPE_3
4 ... SIU WITH TDS FUNCTIONALITY
5 ... ANI SIGNALLING CIS
6 ... CIS MULTIFREQUENCY
7 ... LINE TESTING RURAL
F35:
not applicable anymore
F36:
FOR SLC24 BOARDS ONLY LWVAR 7 IS VALID.
F37:
INSUFFICIENT MEMORY (AMO DIMSU: PARAMETER <param>)
F38:
TSI’S ON PEN <ltg.ltu.slot.cct> COULD NOT BE SET TO SIGNED OFF
F39:
A DEVICE IS CONFIGURED ON PEN <ltg.ltu.slot.cct> -
SIGNING OFF ONLY POSSIBLE WITH AMO DSSU
F40:
NO FREE LINES ARE AVAILABLE IN THE SPECIFIED LTG
F41:
NO SIUP MODULES ALLOWED ON RMS
F42:
FOR SPECIFIED BOARD THE PARAMETER CIRCNT HAS TO BE WITHIN
THE RANGE <satz> TO <maxsatz>.
F43:
OPMODE UN20H85V IS ONLY VALID FOR US RING GENERATOR
F44:
CIRCUIT 0 FOR SPECIFIED BOARD MUST NOT BE SIGNED OFF OR RELEASED
BY AMO-BCSU
THIS CIRCUIT WILL BE USED FROM TELECOMMUTING SERVER FOR
ADMINISTRATE PURPOSES (AMO-SBCSU)
F45:
NO MORE THAN FOUR TSI’S PER CIRCUIT CAN BE SET TO SIGNED OFF
OR CONNECTED FOR VOICE SERVICE
F46:
FOR THE SLMQ MODULE WITH DEVTYPE=OPTISET ONLY ONE TSI PER
CIRCUIT CAN BE SET TO SIGNED OFF OR CONNECTED FOR VOICE SERVICE
F47:
not applicable anymore
F48:
NO MORE THAN TWO TSI'S PER SLMO CIRCUIT WITH DEVTYPE=OPTISET
CAN BE SET TO SIGNED OFF OR CONNECTED FOR VOICE SERVICE
F49:
NO MORE THAN THREE TSI'S PER SLMO/SLMQ CIRCUIT CAN BE SET
TO SIGNED OFF OR CONNECTED FOR VOICE SERVICE
F50:
BEFORE SETTING ANY TSI TO SIGNED OFF ON SLMO CIRCUITS ALWAYS
A TSI HAS TO BE SET TO SIGNED OFF FIRST WITH DEVTYPE=OPTISET
F51:
SIGNOFF OR RELEASE OF CIRCUITS OR TSI'S IS NOT POSSIBLE ON THE
RESPECTIVE BOARD
F52:
PEN <ltg.ltu.slot.cct tsi> IS NOT SET TO SIGNED OFF -
SETTING TO NOT CONNECTED NOT POSSIBLE
F53:
INVALID CIRCUIT NUMBER n FOR SPECIFIED BOARD
SPECIFIED BOARD HAS n CIRCUITS, STARTING AT ZERO
F54:
CONFIGURATIONS CONCERNING LTUC/NCUI BOARDS MUST BE DONE WITH AMO-UCSU
F55:
OPTISET MASTER MUST ALWAYS BE CONFIGURED AT TSI=1
F56:
OPTISET MASTER MUST BE THE LAST TSI TO BE RELEASED
F57:
THE TELEWORKING STATION CANNOT BE ADDED. THE CONTRACTED NUMBER OF
<contrnr> TELEWORKING STATIONS IS REACHED.
PLEASE USE THE DISP-CODEW FOR DISPLAY OF THE CONTRACTED FEATURE PACKAGES
PLEASE CONTACT YOUR SERVICE CENTER IF YOU WISH TO USE
ONE OF THESE FEATURES
F58:
NO CONFIGURATIONS CAN BE DONE DURING SHELF BROADCAST
F59:
THE SPECIFIED BOARD COULD NOT BE ENTERED INTO REFERENCE CLOCK TABLE
F60:
FOR SPECIFIED BOARD THE SPECIFIED MFCTYPE
<mfcerr> IS NOT VALID
F61:
FOR SPECIFIED BOARD NO RANGE OF PENS IS PERMITTED
F62:
THE SPECIFIED BOARD IS ONLY ALLOWED IN LTU 1 TO <ltu>
F63:
IF THE SMALL VERSION OF POWER SUPPLY IS USED (PSDSC) ONLY
@@ BOARDS CAN BE ADDED IN LTU @@
FOR MORE BOARDS USE STRONGER VERSION (PSAFE) OF POWER SUPPLY
F64:
FOR BOARD @@-@@@-@@@ IT IS NOT ALLOWED TO CONFIGURE
FLOW CONTROL VALUES
F65:
THE LONG TERM VALUE (LTERM) FOR FLOW CONTROL MUST NOT BE SMALLER
THAN THE SHORT TERM VALUE (STERM)
F66:
SPECIFIED HIGHWAY BUNDLE NOT VALID FOR THIS BOARD.
F67:
HIGHWAY BUNDLE @ CAN NOT BE ASSIGNED, BECAUSE STANDARD LTU @@ IS NOT
CONFIGURED WITH AN OVERLAY LTU.
F68:
THE BOARD ON @@-@@-@@@ CAN NOT BE CHANGED, BECAUSE THE ASSIGNED
HIGHWAY BUNDLE @ IS NOT ALLOWED FOR THE NEW BOARD.
PLEASE DELETE BOARD FIRST AND THEN ADD THE NEW BOARD, OR CHANGE THE
ASSIGNED HIGHWAY BUNDLE WITH CHANGE-BCSU:HWYBDL
F69:
BOARDS OF THE ENTERED TYPE MAY NOT BE CONFIGURED
F70:
THE MAXIMUM AMOUNT OF CONFIGURABLE BOARDS OF THE ENTERED TYPE
IS ALREADY REACHED.
ANOTHER BOARD MAY NOT BE CONFIGURED.
F71:
NO MORE SUBSCRIBER CAN BE SIGNED OFF, BECAUSE THE CONTRACTED NUMBER OF
@@@@@ FLEX+TDM LICENSES ARE REACHED.
PLEASE USE DISP-CODEW FOR DISPLAY OF THE CONTRACTED FEATURE PACKAGES.
PLEASE CONTACT YOUR SERVICE CENTER IF YOU WISH TO USE
ONE OF THESE FEATURES.
F72:
ENTERED MODULE CODE NUMBER IS INVALID
F73:
DEVTYPE=OPTISET IS ONLY ALLOWED FOR SLMO CIRCUITS
F74:
DEVTYPE=API NOT ALLOWED, IF THERE ARE ALREADY CONFIGURED DEVICES
FOR SERVICE DATA
F75:
not applicable anymore
F76:
PARAMETER LWPAR (LOADWARE BLOCK INDEX) MAY BE CHANGED WITH AMO BCSU
ONLY FOR TMDN-BOS/DIU2U-BOS BOARDS. PLEASE USE AMO TDCSU TO CHANGE THIS
PARAMETER FOR THE CONFIGURED BOARD
F77:
THE TDS PORT UPDATE TO THE DATABASE WAS UNSUCCESSFUL
F78:
ON THIS BOARD ONLY THE FOLLOWING TSIS MAY BE SIGNED OFF:
- IF THE ENTERED DEVICETYPE IS OPTISET OR API:
TSI 1: AS OPTISET
TSI 2: AS API
- IF NO, OR A DIFFERENT DEVICETYPE THAN OPTISET OR API WAS ENTERED:
TSI 1: IN THIS CASE THE DEVICETYPE WILL BE IGNORED.
F79:
INSUFFICIENT MEMORY FOR STMI BOARDS. PLEASE INCREASE MEMORY WITH
AMO DIMSU (PARAMETER: STMI).
F80:
NO LS NET CONFIGURED
PLEASE CONFIGURE LS NET BY MEANS OF ADD-SIPCO
F81:
ENTERED IP ADDRESS IS INVALID.
POSSIBLE REASONS:
- IP ADDRESS IS NOT WITHIN THE VALID RANGE.
THE VALID RANGE WITHIN LS NET IS BETWEEN:
@@@.@@@.@@@.@@@ AND @@@.@@@.@@@.@@@
F82:
BOARDS MAY ONLY BE CONFIGURED IN CERTAIN TYPES OF LTUS. THE VALID
LTU TYPES FOR THE ENTERED BOARD DO NOT MATCH THE LTU TYPE OF LTU n.
BOARD MAY NOT BE CONFIGURED.
F83:
ON A SLMQ3 BOARD ONLY TSI 1 MAY BE SIGNED OFF.
POSSIBLE ERROR REASONS:
- YOU DID NOT ENTER A VALUE FOR PARAMETER TSI
- YOU ENTERED A TSI HIGHER THAN 1 OR A TSI RANGE
- TSI 1 IS ALREADY SIGNED OFF OR CONFIGURED
F84:
NO IPGW BOARD (STMI) CONFIGURED ON ENTERED PEN.
ONLY IPGW BOARDS CAN BE CHANGED WITH ENTERED AMO BRANCH.
F85:
A TMD-MOS/DIU2U-BOS BOARD IS CONFIGURED AT ENTERED PEN. WITH CHANGE-BCSU
PARAMETERS MAY ONLY BE CHANGED FOR TMD-BOS/DIU2U-MOS BOARDS.
F86:
ENTERED SIU BOARD CAN NOT BE CONFIGURED.
REASON:
- ONLY ONE TDS PORT MAY BE CONFIGURED IN THE WHOLE HHS LTU RANGE
- ONLY ONE TDS PORT MAY BE CONFIGURED IN EACH AP LTU
THIS TDS PORT IS ALREADY CONFIGURED:
- IF YOU ENTERED A LTU WITHIN THE HHS RANGE, EITHER THE CENTRAL SIU
HAS TDS FUNCTIONALITY (CONFIGURED WITH AMO UCSU), OR A PERIPHERAL
SIU WITH TDS FUNCTIONALITY WAS ALREADY ADDED.
- IF YOU ENTERED A LTU WITHIN THE AP RANGE, THIS TDS PORT WAS
CONFIGURED, WHEN THE NCUI BOARD (AMO UCSU) WAS ADDED.
F87:
GIVEN IP ADDRESS IS ALREADY CONFIGURED IN THE SYSTEM AND CANNOT BE USED
F88:
THE DESIRED CONFIGURATION CANNOT BE DONE BECAUSE IN TOTAL THE CONFIGURED VIRTUAL GATEWAYS NEED MORE PORTS THAN THE ACTUAL SOFTGATE TYPE ALLOWS.
F89:
THE GIVEN FUNCTION BLOCK IS NOT COMPLETLY CONFIGURED. PLEASE FINISH CONFIGURATION BY MEANS OF AMO-BFDAT FIRST.
F90:
THE GIVEN FUNCTION BLOCK IS NOT USABLE FOR THE GIVEN CGW BOARD.
POSSIBLE REASONS ARE :
- THE POSSIBLE FUNCTION BLOCK TYPES DO NOT MATCH
- IN TOTAL LESS B-CHANNELS ARE AVAILABLE ON CGW THAN CONFIGURED
- SOFTGATE CONFIGURATIONS NEED OWN FUNCTION BLOCKS WITH ATTR SOCO
- CGW CONFIGURATIONS NEED OWN FUNCTION BLOCKS WITHOUT ATTR SOCO
- STMIX DOES NOT SUPPORT WAML FUNCTION
F91:
THE GIVEN BOARD TYPE IS NOT ALLOWED ON RG8300.
F92:
IPV6 AND DHCP FUNCTIONALITY IS SUPPORTED ONLY FOR SOFTGATES.
F93:
PARAMETER IPMODE CAN BE CHANGED TO IPV6 OR DUALSTCK FOR SOFTGATE BOARDS CONFIGURED FOR SIP TRUNKING AND SIP SUBSCRIBER.
F94:
SAME MAC ADDRESS CANNOT BE USED TWICE. MAC ADDRESS SHOULD BE UNIQUE.
F95:
TDMLAW PARAMETER CAN ONLY BE USED FOR HIPATH ACCESS TRUNK BOARDS.
F96:
CMIV30 HAS TO BE SET BY MEANS OF CHA-ZANDE:TYPE=ALLDATA,CMIV30=YES;
F97:
MAC ADDRESS NOT ALLOWED FOR THIS BOARD TYPE.
F98:
SG VIRTUAL BOARDS CANNOT BE CHANGED TO CLASSIC.
F99:
ALARM NUMBER CAN BE CHANGED ONLY ON DEACTIVATED BOARDS.
(DEA-BSSU:OFFTYPE=DI,LTG=@@,LTU=@@,SLOT=@@@;)