84.4
Parameter Description
BTONE
Duration of busy tone
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
10 s
BTSUPV
Supervision time after end of barred trunk service
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
100 ms
BURST
Delayed burst ring with ON1 & ON3 for AUN, CHESE for all digital devices
(see also AMO CTIME, parameter NOTRNG with PERIOD3/PERIOD1)
see FuE Call Pickup Groups PUG
see FuE CHESE Integrated Exec./Sec. System
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
15 s
BUSY
Delay between deactivating SIU type 3 and busy tone
(in accordance with CCITT recommendation Q.475)
see FuE Line Circuits
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
75 ms
CCMED1
Minimum delay between 2 events on the multi-paging system.
The timer is allocated by means of parameter "TBT" of AMO TSCSU.
Type of Input
:
Single value, optional
Possible Values
:
20 - 50000 ms
Default Value
:
500 ms
CCMED2
Minimum delay between 2 events on the multi-paging system.
The timer is allocated by means of parameter "TBT" of AMO TSCSU.
Type of Input
:
Single value, optional
Possible Values
:
20 - 50000 ms
Default Value
:
999 ms
CCMEOD1
EOD delay supervision for multi-paging system (Absence/Paging)
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
4 s
CCMEOD2
EOD delay supervision for multi-paging system (Absence/Paging)
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
7 s
CCSTAD
Dialing supv. (EOD delay) for switchable (single/multi) paging system. The end-of-dial signal is delayed as a control for the two TCOM trunk modules. If no EOD signal is received during the delay time, a message is sent to the dependability system.The timer is allocated by means of parameter "STADIAL" of AMO TSCSU
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
300 s
COOFF1
Pause length for double burst ring 1 (1st pause)
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
400 ms
COOFF2
Pause length for double burst ring 1 (2nd pause)
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
4000 ms
CO1ON
Pulse length for double burst ring 1 (1st pulse)
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
300 ms
CO2ON
Pulse length for double burst ring 1 (2nd pulse)
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
300 ms
CTLSTST1
controlled trunk and line selection test1
Type of Input
:
Single value, optional
Possible Values
:
0 - 300 s
Default Value
:
2 s
CTLSTST2
controlled trunk and line selection test2
Type of Input
:
Single value, optional
0 - 300 s
Possible Values
:
Default Value
:
2 s
CTLSTST3
controlled trunk and line selection test3
Type of Input
:
Single value, optional
Possible Values
:
0 - 300 s
Default Value
:
2 s
CTPRESEL
Timer for controlling the Manual Preselection on an idle line
see FuE Integrated Key Functionality Multiline access
Type of Input
:
Single value, optional
Possible Values
:
2 - 60 s
Default Value
:
10 s
CYCSET
Cyclic setup of line alarms for pulse signaling systems
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
900 s
DANN1
Duration of announcement 1 (feature ADA Thailand)
Type of Input
:
Single value, optional
Possible Values
:
1 - 60000 ms
Default Value
:
24000 ms
DANN2
Duration of announcement 2 (feature ADA Thailand)
Type of Input
:
Single value, optional
Possible Values
:
1 - 60000 ms
Default Value
:
24000 ms
DD1TS
Delayed display with time supervision
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
5 s
DD1NTS
Delayed display without time supervision
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
5 s
DD2NTS
Delayed display without time supervision
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
5 s
DIALIDLE
Time supervision for dialog menu in idle state
Type of Input
:
Single value, optional
Possible Values
:
2 - 20 sec.
Default Value
:
5 sec.
DIALPAU
Inter-digit pause length supervision (see AMO-DTIM2, parameter ANATN)
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
30 s
DISDEL
Delete display after timeout
For all time limited displays, except negativ displays (e.g. “not possible”). They are administrated with parameter DISPNEG.
see FuE Call Pickup Groups PUG
Type of Input
:
Single value, optional
Possible Values
:
1 - 254 s
Default Value
:
5 s
DISPNEG
timer for negativ display
e.g. “not possible”
Type of Input
:
Single value, optional
Possible Values
:
1 - 254 s
Default Value
:
2 s
DITL1
Display immediately with time limit.
The timer is allocated by means of parameter "STADIAL" of AMO TSCSU
Sets the display time for terminal displays
- when the user answers a call
- after the user has finished dialing an external number
(To set the display time for either the dialed external number or for display after answer, the three parameters DD1NTS, DD2NTS and DITL1 must be set.
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
20 s
DITR
timer for recall on hkz trunk with feature ditr
Type of Input
:
Single value, optional
Possible Values
:
500 - 60000 ms
Default Value
:
5000 ms
DITS1
Display immediately with time supervision
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
5 s
DSUPVG
Dialing supervision after outgoing line seizure
Type of Input
:
Single value, optional
Possible Values
:
1 - 300 s
Default Value
:
10 s
DSUPVOP
Dialing supervision after 1st outpulsed digit
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
40 s
DTDEL
Selayed dial tone, incoming
Type of Input
:
Single value, optional
Possible Values
:
0 - 10000 ms
Default Value
:
0 ms
DTONE
Duration of data tone
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
5 s
EOD
Minimum delay between arrival of last pulse and sending EOD signal
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
250 ms
EODACK
Minimum delay between end-of-dialing and answer (acknowledgement)
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
250 ms
EODBSY
Time for end-of-loop-dial busy recognition by main-PABX set
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
250 ms
EODDEL
Delayed end of dialing, outgoing
Type of Input
:
Single value, optional
Possible Values
:
500 - 32000 ms
Default Value
:
2000 ms
FEEDSUPV
Supervision of sub-PABX feed current for outgoing calls from main-PABX set
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
700 ms
HWTEST
Time supervision for hardware settings and terminal test
Type of Input
:
Single value, optional
Possible Values
:
5 - 20 sec.
Default Value
:
10 sec.
INITREQ
Zeitüberwachung für Antworten oder Option nach Einschalten bzw. Reset
Eingabeart
:
Einzelwert, wahlfrei
Mögliche Werte
:
5 - 100 sek.
Standardwert
:
6 sek.
LASUPV1
Line alarm supervision time
The timer is allocated by means of parameter "SUPV" of AMO TSCSU.
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
10 s
LASUPV2
Line alarm supervision time
The timer is allocated by means of parameter "SUPV" of AMO TSCSU.
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
20 s
LASUPV3
Line alarm supervision time
The timer is allocated by means of parameter "SUPV" of AMO TSCSU.
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
LASUPV4
Line alarm supervision time
The timer is allocated by means of parameter "SUPV" of AMO TSCSU.
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
60 s
LASUPV5
Line alarm supervision time
The timer is allocated by means of parameter "SUPV" of AMO TSCSU.
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
300 s
LCRADVT
Duration of route advance delay tones (feature LCR: Expensive Route Tone)
Type of Input
:
Single value, optional
Possible Values
:
100 - 2000 msec.
Default Value
:
300 msec.
LCRET
Expensive route tone supervision (feature LCR: Expensive Route Tone)
Type of Input
:
Single value, optional
Possible Values
:
2 - 10 sec.
Default Value
:
5 sec.
LOOPACK
Minimum time for application of loop after feeding from sub-PABX
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
400 ms
LOOPIN
Supervision of loop start in sub-PABX after line seizure
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
250 ms
LRSUPV
Supervision of line readiness after connection cleardown
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
20 s
MIDENT
Time for identification of job in main-PABX
(TMCL in main-PABX, DEV = MAINMFC)
Type of Input
:
Single value, optional
Possible Values
:
10 - 40 s
Default Value
:
20 s
MINGR
Minimum delay for ground return
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
200 ms
MTOFF
Pause length for multitone ring
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
4000 ms
MTON
Pulse length for multitone ring
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
1000 ms
NORMOFF
Pause length for single burst ring 1
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
4000 ms
NORMON
Pulse length for single burst ring 1
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
1000 ms
OVR
Override release supervision for branch lines
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
1000 ms
OVRSEP
Minimum pause between 2 override pulses
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
200 ms
PAUDIAL
Minimum time between arrival of start-of-dial signal and outpulsing
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
200 ms
PEODMS
Pause before eod delay on did with ms trunk
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
500 ms
PREDIAL
Delay before outpulsing on main-PABX set
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
100 ms
PTNRSUPV
Supervision of ready state of far-end system;
supv. of cleardown ack.
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
5 s
RASTA
Recorded announcement answering text time
see FuE Announcement Unit
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
10 s
RATX
Recorded announcement text time
see FuE Announcement Unit
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
300 s
RBANSW
Answ. i/c CO call ringback after called party release
Type of Input
:
Single value, optional
Possible Values
:
1 - 300 s
Default Value
:
8 s
RECAMDLY
Delay on start of answer text for recorded announcement
see FuE
Announcement Unit
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
14 s
REMBLK
Minimum remote blockage duration on main-PABX set
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
600 ms
REMBLKAC
Minimum remote blockage duration on AC tie-line circuit
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
10 s
RESET1
Outgoing line reset delay after connection cleardown
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
700 ms
RESET2
Outgoing line reset delay after connection cleardown
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
1500 ms
RESET3
Outgoing line reset delay after connection cleardown
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
250 ms
RESET4
Outgoing line reset delay after connection cleardown
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
50 ms
RESET5
Outgoing line reset delay after connection cleardown
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
350 ms
RESTRTNA
timer for restarting North America analog procedure
Type of Input
:
Single value, optional
Possible Values
:
20 - 300 s
Default Value
:
180 s
RESZ
Minimum delay through outgoing trunk reseize bar
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
300 ms
RESZI
Outgoing reseize barring after an incoming C0 call
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
10 s
RESZO
Outgoing reseize barring after an outgoing CO call
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
3 s
RLSA
Main/satellite loop set release time
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
600 ms
RLSB
Main/satellite loop set release time
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
900 ms
RLSC1
Carrier frequency set release acknowledgement time
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
1200 ms
RLSC2
Carrier frequency set release acknowledgement time
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
2500 ms
RLSGRD
Release guard after called party release
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
200 ms
RLSPUL
Forward release pulse length
The time entered here must be at least as long as the longest time required by the various devices connected to the TCOM.
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
500 ms
RLSSUPV
Release receive supervision time
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
250 ms
RNG
Delay between deactivating SIU type 3 and ring tone
(in accordance with CCITT recommendation Q.475)
see FuE Line Circuits
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
500 ms
SECDT
Secondary dial tone supervision
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
5 s
SETUPULS
Trunk setup supervision, pulse signaling system
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
25 s
SIGDEL
Minimum delay between 2 ground signals (consultation, cons. cancel)
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
200 ms
SR1OFF
Pause length for single burst ring 2
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
1000 ms
SR1ON
Pulse length for single burst ring 2
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
1000 ms
SR21OFF
Pause length for double burst ring 2 (1st pause)
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
400 ms
SR21ON
Pulse length for double burst ring 2 (1st pulse)
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
300 ms
SR22OFF
Pause length for double burst ring 2 (2nd pause)
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
1000 ms
SR22ON
Pulse length for double burst ring 2 (2nd pulse)
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
300 ms
STADEL
Minimum delay before start-of-dialing
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
100 ms
STADIAL
Start-of-dial supervision
Type of Input
:
Single value, optional
Possible Values
:
0 and 20-999 ms
Default Value
:
0 ms
SVCMENU
Time supervision for service menu
Type of Input
:
Single value, optional
Possible Values
:
20 - 200 sec.
Default Value
:
60 sec.
SZACK1
Timeout for arrival of seize acknowledgement
The timer is allocated by means of parameter "ACKT" of AMO TSCSU.
Type of Input
:
Single value, optional
Possible Values
:
20 - 50000 ms
Default Value
:
200 ms
SZACK2
Timeout for arrival of seize acknowledgement
The timer is allocated by means of parameter "ACKT" of AMO TSCSU.
Type of Input
:
Single value, optional
Possible Values
:
20 - 50000 ms
Default Value
:
500 ms
SZAT
Clock test before seize attempt
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
1 s
SZSUPV
Supervision time on seize acknowledgement after outgoing seize attempt
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
1 s
TEST1
Time for repeat of release signal if not acknowledged
Type of Input
:
Single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
200 ms
TEST2
Time for repeat of nth test seizure
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
30 s
TINT1
control timer for terminal init procedure
Type of Input
:
Single value, optional
Possible Values
:
1 - 30 s
Default Value
:
20 s
TRACCO
Timer for call tracing of incoming calls from central office
- Tracer not activated if user does not answer within a specified time limit (N2 and R2)
- Output of tracing data to printer when outgoing connection is released, if not cleared down
by central office within specified time limit (received with R2 signaling)
- Output of message RELEASED DESPITE TRACING to printer, if central office clears down
connection within specified time limit in spite of trace request
see FuE TRACE Malicious Call Tracing
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 s
Default Value
:
50 s
TSUPV1
Test run timer 1
see FuE MFC-R2 Signalling/Rest of World ,
see FuE Line Circuits
Type of Input
:
Single value, optional
Possible Values
:
1 and 20 - 60000 ms
Default Value
:
6500 ms
The significance of parameter TSUPV1 depends on the value entered for TESTNO in the AMO TACSU:
TESTNO=1
Length of the ring tone in the test program after dialing the
test loop from central office (Switzerland)
6500
TESTNO=2
Delay until answered (Belgium)
2000
TESTNO=3
No significance
1
TESTNO=4
Length of the ring tone (South Africa)
4500
TESTNO=5
No significance
1
.
.
TESTNO=26
No significance
1
TESTNO=27
Length of the ring tone (CIS)
13000
TSUPV2
Test run timer 2
see FuE MFC-R2 Signalling/Rest of World ,
see FuE Line Circuits
Type of Input
:
Single value, optional
Possible Values
:
1 and 20 - 60000 ms
Default Value
:
10000 ms
The significance of parameter TSUPV2 depends on the value entered for TESTNO in the AMO TACSU:
TESTNO=1
Length of the test tone in the test program after dialing the
test loop from central office. A busy signal is then sent back
to the central office, and a release acknowledgement signal
is awaited (Switzerland)
10000
TESTNO=2
Delay before test tone (Belgium)
1500
TESTNO=3
No significance
1
TESTNO=4
Length of test tone (South Africa)
5000
TESTNO=5
No significance
1
.
.
TESTNO=26
No significance
1
TESTNO=27
Length of test tone 1 (CIS)
2500
TSUPV3
Test run timer 3
see FuE MFC-R2 Signalling/Rest of World ,
see FuE Line Circuits
Type of Input
:
Single value, optional
Possible Values
:
1 and 20 - 60000 ms
Default Value
:
1 ms
The significance of parameter TSUPV3 depends on the value entered for TESTNO in the AMO TACSU:
TESTNO=1
No significance
1
TESTNO=2
No significance
1
TESTNO=3
No significance
1
TESTNO=4
No significance
1
TESTNO=5
No significance
1
.
.
TESTNO=26
No significance
1
TESTNO=27
Pause after test tone 1 (CIS)
5500
TSUPV4
Test run timer 4
see FuE MFC-R2 Signalling/Rest of World ,
see FuE Line Circuits
Type of Input
:
Single value, optional
Possible Values
:
1 and 20 - 60000 ms
Default Value
:
5500 ms
The significance of parameter TSUPV4 depends on the value entered for TESTNO in the AMO TACSU:
TESTNO=1
No significance
1
TESTNO=2
No significance
1
TESTNO=3
No significance
1
TESTNO=4
No significance
1
TESTNO=5
No significance
1
.
.
TESTNO=26
No significance
1
TESTNO=27
Length of test tone 2 (CIS)
500
TSUPV5
Test run timer 5
see FuE MFC-R2 Signalling/Rest of World ,
see FuE Line Circuits
Type of Input
:
Single value, optional
Possible Values
:
1 and 20 - 60000 ms
Default Value
:
500 ms
The significance of parameter TSUPV5 depends on the value entered for TESTNO in the AMO TACSU:
TESTNO=1
No significance
1
TESTNO=2
No significance
1
TESTNO=3
No significance
1
TESTNO=4
No significance
1
TESTNO=5
No significance
1
.
.
TESTNO=26
No significance
1
TESTNO=27
No significance
1
TYPEDH
Desired timer category
see FuE Timers
Type of Input
:
Single value, optional
Possible Values
ALTA
Timers for austrian branch line (alternate route)
CO
Timers for central office trunk calls
DIGITE
Timers for DIGITE
EXPTONE
Timers for Expensive route tone supervision
MFCDID
Timers for MFC indialing and test program
MTLC
Timers for the main-PABX set
STN
Timers for stations in general
TCOM
Timers for the adapter set for special equipment
(e.g. CC, dictation equipment)
TIE
Timers for inter-PABX calls
VCHAPAU
Pause length for alerting tone during
voice calling / handsfree answering (see VCHATONE)
Type of Input
:
Single value, optional
Possible Values
:
1 - 60 s
Default Value
:
20 s
VCHATONE
Pulse length for alerting tone during
voice calling / handsfree answering (see VCHAPAU)
Type of Input
:
Single value, optional
Possible Values
:
20 - 300 ms
Default Value
:
100 ms
VCTONE
Voice call tone
Type of Input
:
Single value, optional
Possible Values
:
555 - 9999 ms
Default Value
:
1000 ms
VWKONFMB
timeout for view conference members dialog
Type of Input
:
Single value, optional
Possible Values
:
1-254 sec.
Default Value
:
5 sec.
WAITDTMF
Delayed switching of voice connections for DTMF calls to CO if PAR=NO1A (AMO COP) and if dialing was terminated using # (SFRM set) to prevent the DTMF signal sent by the terminal
Type of Input
:
Single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
1000 ms
WANN1
Wait for announcement 1 (feature ADA Thailand) (see parameter DANN1)
Type of Input
:
Single value, optional
Possible Values
:
1 - 60000 ms
Default Value
:
30000 ms
WANN2
Wait for announcement 2 (feature ADA Thailand) (see parameter DANN2)
Type of Input
:
Single value, optional
Possible Values
:
1 - 60000 ms
Default Value
:
30000 ms
WFIRST
Max. wait time until first announcement
see FuE Announcement Unit, Synchronized Announcements
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 sec.
Default Value
:
15 sec.
WNEXT
Time supervision until next announcement
see FuE Announcement Unit, Synchronized Announcements
Type of Input
:
Single value, optional
Possible Values
:
1 - 9999 sec.
Default Value
:
60 sec.