85.4
Parameter Description
ACBK1
Break timing for tie trunk, AC signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
60 ms
ACBK2
Break timing for tie trunk, AC signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
40 ms
ACKTN1
Station dialling supervision time
Type of Input
:
single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
3500 ms
ACMK1
Make time for tie trunk, AC signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
40 ms
ACMK2
Make time for tie trunk, AC signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
60 ms
AICSZIPT
AICS ZIP Tone
Type of Input
:
single value, optional
Possible Values
:
500 - 1600 ms
Default Value
:
1600 ms
ANATN
Time for disconnection of tone from ANATE
Type of Input
:
single value, optional
Possible Values
:
1 - 9999 sec
Default Value
:
10 sec
BKFO
Impulse timing on exchange central office trunks (according to Telecommunications Regulations)
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
60 ms
BKIN
Impulse timing on exchange central office trunks (international)
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
BSGNL1
Max. duration of busy signal 1
Type of Input
:
single value, optional
Possible Values
:
1 - 9999 sec
Default Value
:
15 sec
BSGNL2
Max. duration of busy signal 2
Type of Input
:
single value, optional
Possible Values
:
1 - 9999 sec
Default Value
:
30 sec
BSGNL3
Max. duration of busy signal 3
Type of Input
:
single value, optional
Possible Values
:
1 - 9999 sec
Default Value
:
60 sec
BSIGCONN
Time to connect a busy signal
Type of Input
:
single value, optional
Possible Values
:
5 - 60 sec
Default Value
:
30 sec (for France: 5 sec)
BSYON
Busy tone "on" time
Type of Input
:
single value, optional
Possible Values
:
1 - 9999 sec
Default Value
:
10 sec
CCBK1
Pulse timing for code call module
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
60 ms
CCBK2
Pulse timing for code call module
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
CCMK1
Pause time for code call module
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
CCMK2
Pause time for code call module
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
CMPOBEEP
cycle time of the beep cycle
Type of Input
:
single value, optional
Possible Values
:
20 - 999 msec
Default Value
:
60 msec
CRFIND
Time to find free code receiver
(or sender if none had previously been found)
see Voice Mail Service External
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
300 ms
CUTTHRUD
Time required to connect a DTMF receiver, e.g. after seizure of a cut-through dialing line
Type of Input
:
single value, optional
Possible Values
:
2 - 70 sec
Default Value
:
15 sec
DELTIM1
Timer 1 for delay time until sending of ANI codogram (CIS)
Type of Input
:
Single value, optional
Possible Values
:
0, 1 - 9999 msec.
Default Value
:
0 msec.
DELTIM2
Timer 2 for delay time until sending of ANI codogram (CIS)
Type of Input
:
Single value, optional
Possible Values
:
0, 1 - 9999 msec.
Default Value
:
0 msec.
DIALPAUT
Inter digit timing for ANATE
Type of Input
:
single value, optional
Possible Values
:
1 - 9999 sec
Default Value
:
30 sec
DIALSTA
Supervision time when no dialling occurs
(dialling is not started or continued in incoming trunk traffic)
Type of Input
:
single value, optional
Possible Values
:
1 - 9999 sec
Default Value
:
30 sec
DTNT1
Station dialling supervision time
Type of Input
:
single value, optional
Possible Values
:
1 - 9999 sec
Default Value
:
10 sec
DTRFIND
Time to find an available dial tone receiver
(if none was found previously)
Type of Input
:
single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
300 ms
EBK1
Impulse timing for E&M tie trunk
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
60 ms
EBK2
Impulse timing for E&M tie trunk
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
EMK1
Pause time for E&M tie trunk
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
40 ms
EMK2
Pause time for E&M tie trunk
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
EMMK1
Make time for tie trunk, carrier frequency signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
40 ms
EMMK2
Make time for tie trunk, carrier frequency signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
EOD
End-of-dial timing without 1A dialling scheme
Type of Input
:
single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
3000 ms
EOD1A
End-of-dial timing with 1A dialling scheme
The value of EOD1A must not be less than the value of parameter SPDPD IN AMO CTIME.
Type of Input
:
single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
5000 ms
FAUXTN1
First burst of auxiliary tone
Type of Input
:
single value, optional
Possible Values
:
100 - 2000 ms
Default Value
:
500 ms
FAUXTN2
First burst of auxiliary tone 2
Type of Input
:
single value, optional
Possible Values
:
100 - 2000 ms
Default Value
:
1000 ms
FCO
First burst of camp-on tone
Type of Input
:
single value, optional
Possible Values
:
100 - 2000 ms
Default Value
:
300 ms
FLSHSUPV
Time for return from consultation after flashing
Type of Input
:
single value, optional
Possible Values
:
1 - 9999 sec
Default Value
:
2 sec
FRNGBK
First burst of ringback tone
Type of Input
:
single value, optional
Possible Values
:
100 - 2000 ms
Default Value
:
800 ms
IDGT1
Inter digit timing for dial pulsing on lines
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
400 ms
IDGT2
Inter digit timing for dial pulsing on lines
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
900 ms
IDGT3
Inter digit timing for dial pulsing on lines
Type of Input
:
single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
1200 ms
IDGT4
Inter digit timing for dial pulsing on lines
Type of Input
:
single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
1500 ms
MAUTO
delay timer of auto connection
Type of Input
:
single value, optional
Possible Values
:
1 - 255 s
Default Value
:
3 s
MBK1
Impulse time for main trunk, loop
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
60 ms
MBK2
Impulse time for main trunk, loop
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
MMK1
Pause time for main trunk, loop
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
40 ms
MMK2
Pause time for main trunk, loop
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
NUTONE
Duration time of nu tone connection
Type of Input
:
single value, optional
Possible Values
:
5 - 60 sec
Default Value
:
10 sec (for France: 30 sec)
OHDELAY1
offhook delay timer.
Type of Input
:
single value, optional
Possible Values
:
100 - 3000 ms
Default Value
:
100 ms
PAUSDIAL
pause time between internal and second dial tone
Type of Input
:
single value, optional
Possible Values
:
0 - 999 msec
Default Value
:
0 msec
PDLY1
Predialling delay
(for lines without start-of-pulsing signal and without tone)
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
500 ms
PDLY2
Predialling delay
(for lines without start-of-pulsing signal and without tone)
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
800 ms
PDLY3
Predialling delay
(for lines without start-of-pulsing signal and without tone)
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
1200 ms
PDLY4
Predialling delay
(for lines without start-of-pulsing signal and without tone)
Type of Input
:
single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
3000 ms
PMKFO
Central office trunk pause time (according to Telecommunications Regulations)
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
40 ms
PMKIN
Central office trunk pause time (international)
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
POSTDIAL
Maximum post dialling delay for analog telephone
Type of Input
:
single value, optional
Possible Values
:
1 - 9999 sec
Default Value
:
10 sec
REQTIM1
Timer 1 for ANI supervision from seizure acknowledgement on (CIS)
Type of Input
:
Single value, optional
Possible Values
:
1 - 60 sec.
Default Value
:
30 sec.
REQTIM2
Timer 2 für ANI-Überwachung ab Belegungsquittung
Type of Input
:
Single value, optional
Possible Values
:
1 - 60 sec.
Default Value
:
30 sec.
RESZBLK
Reseizure blockage for trunk
Type of Input
:
single value, optional
Possible Values
:
20 - 9999 ms
Default Value
:
1500 ms
SBK1
Break time for tie trunk, "simultaneous" signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
60 ms
SBK2
Break time for tie trunk, "simultaneous" signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
SCBK1
Break time for tie trunk, loop signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
60 ms
SCBK2
Break time for tie trunk, loop signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
SCMK1
Make time for tie trunk, loop signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
40 ms
SCMK2
Make time for tie trunk, loop signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
SMK1
Make time for tie trunk, "simultaneous" signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
40 ms
SMK2
Make time for tie trunk, "simultaneous" signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
STADIAL1
Start dial supervision timing (for tone or signal in the case of trunks); (AMO TSCSU, parameter STADIAL) (for dial tone 1)
Type of Input
:
single value, optional
Possible Values
:
1 - 9999 sec
Default Value
:
5 sec
STADIAL2
Start dial supervision timing (for tone or signal in the case of trunks); (AMO TSCSU, parameter STADIAL) (for dial tone 1)
Type of Input
:
single value, optional
Possible Values
:
1 - 9999 sec
Default Value
:
25 sec
STADIAL3
Start dial supervision timing (for tone or signal in the case of trunks); (AMO TSCSU, parameter STADIAL) (for dial tone 2)
Type of Input
:
single value, optional
Possible Values
:
3 - 100 sec
Default Value
:
5 sec
STADIAL4
Start dial supervision timing (for tone or signal in the case of trunks); (AMO TSCSU, parameter STADIAL) (for dial tone 2)
Type of Input
:
single value, optional
Possible Values
:
20 - 300 sec
Default Value
:
25 sec
TACTIV
Activtion timer T-ACTIVE
This timer is started by user A, after sending a CCBS Request invoke component to network A.
Type of Input
:
single value, optional
Possible Values
:
0 - 20 sec
Default Value
:
10 sec
TBK1
Break time for tie trunk, carrier frequency signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
60 ms
TBK2
Break time for tie trunk, carrier frequency signalling
Type of Input
:
single value, optional
Possible Values
:
20 - 999 ms
Default Value
:
30 ms
TCCBS1
Status Check Timer T-CCBS1
The maximum time the network will wait for user A for checking for compatible terminals.
Type of Input
:
single value, optional
Possible Values
:
0 - 8 sec
Default Value
:
4 sec
TCCBS2
CCBS Service Duration Timer T-CCBS2:
The maximum time the network will be active within the network. The value is a network option.
Type of Input
:
single value, optional
Possible Values
:
10 - 60 min
Default Value
:
45 min
TCCBS4
Destination B idle guarde timer T-CCBS4:
The time the network will wait after destination B has becme not busy before indicatting a "CCBS recall" or "Indication of B idle" to user A.
Type of Input
:
single value, optional
Possible Values
:
0 - 30 sec
Default Value
:
15 sec
TCCBS5
Service lifetime supervision timer T-CCBS5:
This timer supervises the lifetime of the signaling connection at the destination public network.
Type of Input
:
single value, optional
Possible Values
:
0 - 80 min
Default Value
:
60 min
TCCBS6
Service lifetime supervision timer T-CCBS6:
This timer supervises the lifetime of the signaling connection at the destination public network.
Type of Input
:
single value, optional
Possible Values
:
0 - 80 min
Default Value
:
60 min
TDEACTIV
Deactivation Timer T-DEACTIVATE:
This timer is started by user A, after sending a CCBS Deactivate invoke component to network A.
Type of Input
:
single value, optional
Possible Values
:
0 - 8 sec
Default Value
:
4 sec
TINTER
Interrogation Timer T-INTERROGATE:
This timer is started by user A, after sending a CCBS Interrogate invoke component to network A.
Type of Input
:
single value, optional
Possible Values
:
0 - 8 sec
Default Value
:
4 sec
TSTATUS
Status Check Timer T-STATUS:
The maximum time the network will wait for user B response for checking for compatible terminals.
Type of Input
:
single value, optional
Possible Values
:
0 - 8 sec
Default Value
:
4 sec
TYPEDH
Desired timer category
see Timers
Type of Input
:
single value, optional
Possible Values
:
DSS1
Call back on DSS1 protocol
GEN
General timers
MKBK
Make/break ratios
LNGEN
General trunk set timers
${DocTitle}
, ID:
${DocID}
©
02/2025
Mitel Networks Corporation. - All rights reserved.
Mitel and the Mitel logo are trademarks of Mitel Networks Corporation. Unify and associated marks are trademarks of Unify Software and Solutions GmbH&Co. KG.
All other trademarks herein are the property of their respective owners.