101.4
Parameter Description
AMOHDR
Name of switch: echoing the header
Type of Input
:
Single value, optional
Possible Values
:
ON, OFF
Default Value
:
ON
AMOOK
Name of switch: test "AMO COMPLETED"
Type of Input
:
Single value, optional
Possible Values
:
ON, OFF
Default Value
:
ON
CMDECHO
Name of switch: echoing of het AMO input on/off
Type of Input
:
Single value, optional
Possible Values
:
ON, OFF
Standard
:
ON
CONFREST
Name of switch: Suppress execution confirmation of AMO-REST
Type of Input
:
Single value, optional
Possible Values
:
ON, OFF
Standard
:
ON
LOGBKOFF
Name of switch: Switch off logging
Type of Input
:
Single value, optional
Possible Values
:
0 till 8
0
NONE
1
EXEC-UPLO/UPLO2
2
DISPLAY( ABFRAGEN) -BUEND
3
REGEN-CPTP
4
CHANGE-FUNCT is not logged
5 - 8
RESERVED
PFI
Name of switch: Power fail interrupt
Type of Input
:
Single value, optional
Possible Values
:
WOUTPFI
WITHPFI
Default Value
:
WOUPFI
POWERSYS
Name of switch: Type of power system
Type of Input
:
Single value, optional
Possible Values
:
ACDCWR = AC/DC With redundancy
ACDCWOR = AC/DC Without redundancy
DCDCWR = DC/DC With redundancy
DCDCWOR = DC/DC Without redundancy
Default Value
:
ACDCWOR = AC/DC Without redundancy
REGIN
REGEN output input usable.
This switch is indicating whether a regen output has to be displayed in the standard format or in the new introduced format which is usable for input. The standard format contains line control sequences and filling blanks.
Type of Input
:
Single value, optional
Possible Values
:
:Y - Yes
N - No
Default Value
:
none
REGKEY
REGEN output display containing keywords.
This switch is indicating whether a regen output has to be displayed in the standard format (position oriented) or in the new introduced format containing keywords.
Type of Input
:
Single value, optional
Possible Values
:
:Y - Yes
N - No
Default Value
:
none
REGLEN
Check REGEN output length for max. input length.
This switch is indicating whether a regen output has to be displayed in the keyword output format only, if the maximum input string length is not exceeded.
Type of Input
:
Single value, optional
Possible Values
:
:Y - Yes
N - No
Default Value
:
none
RETENT
Xenix Retention Time
Type of Input
:
Single value, optional
Possible Values
:
0 to 65535 seconds
RTOADS
Name of switch: Administration server routine test
Type of Input
:
Single value, optional
Possible Values
:
ON, OFF
Default Value
:
ON
RTOTFS
Name of switch: TFS routine test
Type of Input
:
Single value, optional
Possible Values
:
ON, OFF
Default Value
:
ON
RTOVMS
Name of switch: Voice mail server routine test
Type of Input
:
Single value, optional
Possible Values
:
ON, OFF
Default Value
:
ON
SLANG
Name of switch: Select Session specific AM’O language
Type of Input
:
Single value, optional
Possible Values
:
GER: German
ENG: English
Default Value
:
GER
SPLIT
Name of switch: split mode
Type of Input
:
Single value, optional
Possible Values
:
ON, OFF
Default Value
:
OFF
SS7CTR
Name of switch: Type of SS7 conroller attached to the Hicom
Type of Input
:
Single value, optional
Possible Value
:
NO : No controller connected
TUP : Telephone user part controller connected
ISUP : ISDN user part controller connected
Default Value
:
NO
SUSY
Name of switch : Loading indication for SIT
Type of Input
:
Single value, optional
Possible Values
:
ON, OFF
Default Value
:
OFF
VALUE
Optional parameter VALUE introduced to up to now parameterles action DISPLAY. Parameter VALUE can be set with up to 14 single values (all parameters of action change) concatenated with ampersant (&). Standard set of parameter VALUE, when not given, equals all values except SLANG..
Type of Input
:
Single value ore concatenated with &, optional
Possible Value
:
CMDECHO: command echo switch
AMOOK: amo performance display switch
AMOHDR: amo protocol header switch
SUSY: loading indication switch for UBGDAT subsystem in SIT
RTOADS: ADS routine test switch
RTOTFS: TFS routine test switch
RTOVMS: VMSroutine test switch
LANG: AMO text language switch
SPLIT: splitting mode switch
RETENT: XENIX retention time in seconds
POWERSYS: Type of power system
PFI: Interpretation of PFI in power system
SS7CTR: SS7 controller type connected to hicom
SLANG: select session specific amo language
REGIN: regen output input usable
REGKEY: regen output display containing keywords
REGLEN: check regen output length for max. input length
${DocTitle}