131.3
Parameter Description
CARRIER
LCR carrier, always enter in combination with ZONE
Type of Input
:
Single value, optional
Possible Values
:
1 - 9
Default Value
1
CBMATTR
Central Byte Manipulation Attributes
Type of Input
:
single value, optional (ADD, CHANGE)
Possible Values
:
AMC
a-law/m-law conversion
EC128
128 ms echo cancellation
EC128AMC
128 ms echo cancellation with a-law/m-law conversion
EC64
64 ms echo cancellation
EC64AMC
64 ms echo cancellation with a-law/m-law conversion
NOCBM
No CBM attribute
Default value
NOCBM
COTIDX
Class of Trunk Index
Type of Input
:
Single value, optional
Possible Values
:
0 - 255
Default Value
0
DNNO
Destination Node Number, overrides DNNO of the route
Type of Input
:
Up to 3 values, linked by -, optional
Possible Values
:
LEVEL2: 0 - 29
LEVEL1: 0 - 253
LEVEL0: 0 - 999
Default Value
No Entry
FACILITY
Facility number for the call-by-call services FX and TTA
Type of Input
:
Single value, optional (ADD, CHANGE)
Possible Values
:
0-9, up to 5 characters
KIND
Deletion kind
Type of Input
:
Single value, mandatory (DEL)
Possible Values
:
LROUTE -
Delete all LCR route elements from an LROUTE (parameter LROUTE, mandatory)
LRTEL -
Delete individual LCR route elements from an LROUTE (parameters LROUTE and LRTEL mandatory)
LATTR
LCR Attribute
Type of Input
:
Up to 8 values, optional (ADD, CHANGE, DISP)
Possible Values
:
NONE
no LCR-attributes
NOLEV
no precedence level
TRANSGR
Attribute TRANSGROUP
e.g. France: indirect access to a private network using the public network
WCHREG
route element with cdr
NOTRANS
last node with cdr
NOCHDISP
deactivate charge display
INTBNECK
trunk is a bottleneck in the net
INTCHARG
internal charge rates used
EODSTCDR
end of dialling starts cdr
MODEM
modem required
VOICO
Voice compression is used for TGRP
SUPPCPN
Suppress Calling Party Number
TGPRIV
Trunk group to private node
(only for ‘all trunks busy’ indication)
TGPUB
Trunk group to public network
(only for ‘all trunks busy’ indication)
PRIMRTE
Trunk group only for Primary Route
REROUTE
Trunk group only for Reroute
ETEINCPL
End to End., send next digit
ETEMIN0
End to End., repeat last digit
ETEMIN1
End to End., repeat last but first digit
ETEMIN2
End to End., repeat last but second digit
ETEMIN3
End to End., repeat last but third digit
ETEMINX
End to End., repeat all digits
ETENORSP
End to End., no backward sign
EXPRTG
Redirecting will be charged in any case
NOEXTRTE
Trunk group only in private Network routing
OHKQ
Off hook queuing
RERTEINT
Reroute internal
ALTTGR
Alternate trunk group
ONHKQ
On hook queuing
PUBNUM
Send public number as calling party number
PUBNAME
Send public name as calling party name
DMCEND
End of DMC domain
FLASH
MLPP-Level Flash
FLASHOV
MLPP-Level flash override (high level)
IMMED
MLPP-Level Immediate
PRTY
MLPP-Level priority (low level)
RTINE
MLPP-Level Routine
RTINEP
MLPP-Level Routine but protected
LAUTH
Required LCR authorization
(only relevant for LROUTE for LCR or LCR with closed numbering)
This LCR authorization is checked against the LCOS1/2 assigned to one of the users. LCOS1/2 were set up by means of AMO COSSU,TYPE=LCOS.
Type of Input
:
1 to 16 Single values concatenated with &, mandatory (ADD)
1 to 16 Single values concatenated with &, optional (CHANGE)
1 to 10 Single values concatenated with & or &&, optional
if TYPE=LCR/NWLCR (DISPLAY)
Possible Values
:
numeric,1-64
LDSRT
Number of LCR Digit String Restriction Tables
Tables can be defined using AMO LDSRT
Type of Input
:
1 to 16 Single values concatenated with & or &&, optional (ADD, CHANGE, DISPLAY)
Possible Values
:
numeric,1-16
LROUTE
LCR route number
must be defined using the AMO RICHT
Type of Input
:
Single value, mandatory (ADD, CHANGE)
Single value &, &&, mandatory (up to 10 individual concatenations or 5 individual range inputs) if KIND=LROUTE (DEL)
Single value, mandatory if KIND=LRTEL (DEL)
Single value &, &&, optional (DISPLAY,REGEN)
(up to 10 individual concatenations or 5 individual range inputs)
Possible Values
:
1-64000
LRTEL
LCR route element number
Type of Input
:
Single value, mandatory (CHANGE)
Single value &, &&, mandatory
(up to 10 individual concatenations or 5 individual range inputs) if KIND=LRTEL (DEL)
Possible Values
:
1-16384, depending on the DIMSU value LRTEL
LSCHED
LCR schedule
Type of Input
:
1 to 8 Single values concatenated by &, optional (ADD, CHANGE)
Possible Values
:
A
disable element A
AE
mark element A as expensive
B
disable element B
BE
mark element B as expensive
C
disable element C
CE
mark element C as expensive
D
disable element D
DE
mark element D as expensive
E
disable element E
EE
mark element E as expensive
EMPTY
no entry
F
disable element F
FE
mark element F as expensive
G
disable element G
GE
mark element G as expensive
H
disable element H
HE
mark element H as expensive
LSVC
LCR service, use accordingly to AMO RICHT
Type of input
:
single value, optional
Possible values
:
VCE
voice
DTE
data terminal equipment
ALL
VCE and DTE
Default value
:
ALL
LVAL
LCR priority
Type of Input
:
Single value, optional (ADD)
Possible Values
:
1-254
Default Value
:
1 if LRTEL=1 else LVAL (LRTEL max)
LVALNEW
LCR PRIORITY TO BE INSERTED
Type of Input
:
Single value, optional (ADD)
Possible Values
:
1-254
GW1
Destination Gateway 1, consists of gateway number-sector path number
Type of Input
:
2 concatenated values with "-", optional (ADD, CHANGE)
Possible Values
:
0-65535
GW2
Destination Gateway 2, consists of gateway number-sector path number
Type of Input
:
2 concatenated values with "-", optional (ADD, CHANGE)
Possible Values
:
0-65535
GW3
Destination Gateway 3, consists of gateway number-sector path number
Type of Input
:
2 concatenated values with "-", optional (ADD, CHANGE)
Possible Values
:
0-65535
GW4
Destination Gateway 4, consists of gateway number-sector path number
Type of Input
:
2 concatenated values with "-", optional (ADD, CHANGE)
Possible Values
:
0-65535
GW5
Destination Gateway 5, consists of gateway number-sector path number
Type of Input
:
2 concatenated values with "-", optional (ADD, CHANGE)
Possible Values
:
0-65535
GWIDX
Gateway Index
Type of Input
:
Single value, & optional (DELETE)
Up to 3 concatenated values with &
Possible Values
:
1-5
GW
Destination Gateway, consists of gateway number-sector path number
Type of Input
:
Single value, optional (DISPLAY)
Up to 2 concatenated values with "-",
first part is "gateway number" and second part is "sector path number"
Possible Values
:
0-65535
ODR
Outdial rule
(only relevant for LROUTE for LCR or LCR with closed numbering) must be set up using the AMO LODR
Type of Input
:
Single value, mandatory (ADD)
Single value, optional (CHANGE)
Single value &, &&, optional (up to 10 individual concatenations or 5 individual range inputs) if TYPE=LCR/NWLCR (DISPLAY)
Possible Values
:
1-4096
SCCID
Specialized common carrier identifier
Type of Input
:
Single value, optional (ADD, CHANGE)
Possible Values
:
0-9, 4 characters
or *.
Default value
*
SVCNVCE
Service non-voice
Type of Input
:
Single value, optional (ADD, CHANGE)
Possible Values
:
FX
Foreign exchange access
NONE
no attributes
OUTWATS
out Wide Area Telecommunication Service
SDS
Switched digital service
TTA
Tie trunk access
VPN
Virtual Private Network
SVCVCE
Service voice
Type of Input
:
Single value, optional (ADD, CHANGE)
Possible Values
:
FX
Foreign exchange access
LDS
Long distance service
NONE
no attributes
OUTWATS
out Wide Area Telecommunication Service
TTA
Tie trunk access
VPN
Virtual Private Network
WB0
WATS Band 0
WB1
WATS Band 1
WB2
WATS Band 2
WB3
WATS Band 3
WB4
WATS Band 4
WB5
WATS Band 5
WB6
WATS Band 6
WB7
WATS Band 7
WB8
WATS Band 8
WB9
WATS Band 9
TGRP
Trunk group number
must be assigned to LROUTE using the AMO RICHT
Type of Input
:
Single value, mandatory (ADD)
Single value, optional (CHANGE)
Single value &, &&, optional (DISPLAY)
(up to 10 individual concatenations or 5 individual range inputs)
Possible Values
:
1-512
TYPE
LCR route type
Type of Input
:
Single value, mandatory (DISPLAY)
Possible Values
:
LCR
- only LROUTEs for LCR
NWLCR
- only LROUTEs for LCR
with closed numbering (networking LCR)
ALL
- LROUTEs for LCR and NWLCR
VCCYC
Maximum number of voice compression/decompressions cycles
Type of Input
:
Single value, optional
Possible Values
:
1-15
Default Value
:
4
ZONE
LCR zone, always enter in combination with CARRIER
Type of Input
:
Single value, optional
Possible Values
:
EMPTY
no zone
LOCAL
local zone
SHORT (NEAR)
short distance zone 1 - 9
INTERN01 -
internal zone 1 - 9
INTERN09 (INT)
LONG01-LONG50 (DIST)
long distance zone 1 - 50
ABROAD01 -
abroad distance zone 1 - 99
ABROAD99 (ABR)
TIE01 - TIE09
tie zone 1 - 9
Default Value
EMPTY